Quick reference guide for base anchoring and pressure filling
10
SKS 4.0 Series - Flat roof and wall mounting - We reserve the right to make any changes due to technical modifications.
41
10 Quick reference guide for base anchoring and pressure filling
These instructions are only intended as an overview of
the work to be carried out. You MUST follow the detailed
descriptions for the work on the pages mentioned, and
obey all safety and user instructions.
Fig. 62
Installing on a flat roof
Fig. 63
Water connections
Fig. 64
Fitting the collector sensor and connection parts
63043970.48-1.SD
63043970.48-1.SD
1
3
2
4
6
8,10
11,14
16
63043966.31-1.SD
63043966.31-1.SD
12
12
7
7
13
9
17
63043969.07-1.SD
63043969.07-1.SD
19
7
20
12
18
Fitting braces and profile rails
1.
Insert telescopic rails into each other according to
the selected angle of inclination, and fasten.
p. 14
2.
Drill holes in girder (or similar), and fasten collector
braces with screws.
p. 23
3.
Connect profile rails together using plug connectors.
p. 26
4.
Fasten profile rails to collector braces.
p. 27
5.
Align sides of the profile rails.
p. 27
6.
Install anti-slip protectors into the two inner slotted ho-
les on the lower profile rails.
p. 27
Preparing to install the collectors
7.
Push end caps onto those connections that are not
required and secure using brackets.
p. 30
Fastening the collectors
8.
Push single-sided collector clamp (right) into profile
rails.
p. 30
9.
Place first collector (right) onto profile rails and
push onto collector clamp.
p. 31
10.
Screw up collector clamp on the right.
p. 31
11.
Place double-sided collector clamp into profile rail
and push onto first collector.
p. 31
12.
Push corrugated pipe connectors onto the connec-
tions on the first collector and secure with brackets.
p. 32
13.
Push second collector towards the first and fix in
place with brackets.
p. 32
14.
Tighten screws on the double-sided collector clamp.
p. 31
15.
Repeat the procedure for all other collectors.
p. 33
16.
Fit single-sided collector clamps on the left.
p. 33
Header connection
17.
Insert collector sensor as far as it will go into the coll-
ector with the flow line to be connected,
and screw tight.
p. 34
18.
Place holder for flow line onto collector frame and
screw in place.
p. 35
19.
Fasten pipe bend to flow and return connections
using clamping ring and nut.
p. 36
20.
Fix pipe bend with clips.
p. 36
21.
Perform installation checks.
p. 39
22.
Insulate header pipes with UV and high
temperature resistant material.
p. 40