Collector installation
6
SKS 4.0 Series - Flat roof and wall mounting - We reserve the right to make any changes due to technical modifications.
31
Putting the first collector in place
Lay the collector on the profile rails in such a way that
the sensor bush to receive the collector sensor is at the
top. Begin by laying the collectors on the right-hand side
of the profile rails.
z
Place the first collector onto the profile rails and allow
it to slide into the anti-slip protectors (Fig. 45,
Item 2
)
(Fig. 45).
The lower collector edge must lie in the opening of the
anti-slip protector (Fig. 45,
Item 1
).
z
Carefully push collector (Fig. 46,
Item 1
) up against
the single-sided collector clamp and align horizontal-
ly.
z
Screw in single-sided collector clamp using size 5
spanner (Fig. 46,
Item 2
).
The grip (Fig. 46,
Item 2
) on the collector clamp now
grips the lower collector edge.
Inserting a double-sided collector clamp
z
Insert the double-sided collector clamp, nut first, into
the opening made by the profile rail and plug connec-
tor so that the plastic spacer (Fig. 47,
Item 1
) sur-
rounds the profile rail.
z
Push double-sided collector clamp up against the
collector frame.
Fig. 45
Laying the first collector on the profile rails
63043970.32-1.SD
63043970.32-1.SD
1
2
CAUTION!
RISK OF INJURY
Install collectors with at least one assis-
tant.
Fig. 46
Single-sided collector clamp screwed in place
63043965.45-1.SD
63043965.45-1.SD
1
2
USER NOTE
When the screw is tightened, the plastic
guide at the pre-determined cut-off points
breaks away and can be
discarded.
Fig. 47
Fitting a double-sided collector clamp
63043969.02-1.SD
63043969.02-1.SD
1
1
USER NOTE
Do not tighten the screw until the second
collector has been pushed up against the
double-sided collector clamp.