DP41-S
High Performance Strain
Gage Indicator
MQS1291/1205
12458ML-99 Rev. E
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and
workmanship for a period of
one (1) year
from the date of purchase. In addition to OMEGA’s
standard warranty period, OMEGA Engineering will extend the warranty period for
four (4)
additional years
if the warranty card enclosed with each instrument is returned to OMEGA.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer
Service Department will issue an Authorized Return (AR) number immediately upon phone or
written request. Upon examination by OMEGA, if the unit is found to be defective, it will be
repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting
from any action of the purchaser, including but not limited to mishandling, improper interfacing,
operation outside of design limits, improper repair, or unauthorized modification. This
WARRANTY is VOID if the unit shows evidence of having been tampered with or shows
evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture
or vibration; improper specification; misapplication; misuse or other operating conditions outside
of OMEGA’s control. Components which wear are not warranted, including but not limited to
contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability
for any damages that result from the use of its products in accordance with information
provided by OMEGA, either verbal or written. OMEGA warrants only that the parts
manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER
WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR
IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY
WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth
herein are exclusive, and the total liability of OMEGA with respect to this order, whether
based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall
not exceed the purchase price of the component upon which liability is based. In no event
shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1)
as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or
activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or
with any nuclear installation or activity, medical application, used on humans, or misused in any
way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER
language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from
any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN
AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE
DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number
should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to
prevent breakage in transit.
FOR WARRANTY RETURNS, please have
the following information available BEFORE
contacting OMEGA:
1.
Purchase Order number under which the
product was PURCHASED,
2.
Model and serial number of the product
under warranty, and
3.
Repair instructions and/or specific
problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult
OMEGA for current repair charges. Have the
following information available BEFORE
contacting OMEGA:
1. Purchase Order number to cover the
COST of the repair,
2.
Model and serial number of product, and
3.
Repair instructions and/or specific
problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is
possible. This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2005 OMEGA ENGINEERING, INC. All rights reserved. This document may not be
copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-
readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING,
INC.
PATENT AND TRADEMARK NOTICE:
The “Meter Case Bezel Design” is a trademark of
NEWPORT Electronics, Inc., registered in the U.S. USED UNDER LICENSE. This product is
covered by one or more of the following patents: U.S. Pat. No. Des. 336,895; 5,274,577;
6,243,021 / CANADA 2052599; 2052600 / ITALY 1249456; 1250938 / GERMANY DE 41 34398
C2 / SPAIN 2039150; 2048066 / UK Patent No. GB2 249 837; GB2 248 954 / FRANCE BREVET
NO. 91 12756. Other U.S. and International Patents pending or applied for.
This device is marked with the international caution symbol. It is important to read the
Setup Guide before installing or commissioning this device, as the guide contains
important information relating to safety and EMC.
WARNING:
These products are not designed for use in, and should not be used for, patient-
connected applications.
It is the policy of OMEGA
to comply with all worldwide safety and EMC/EMI regulations that apply.
OMEGA
is constantly pursuing certification of its products to the European New Approach Directives.
The information contained in this document is believed to be correct, but OMEGA
Engineering,
Inc.
accepts no liability for any errors it contains, and reserves the right to alter specifications without
notice.
TRADEMARK NOTICE:
®
,
omega.com
®
,and
,
are Trademarks of
OMEGA ENGINEERING, INC.
®
Servicing North America:
USA:
JJ
One Omega Drive, P.O. Box 4047
ISO 9001 Certified
J
Stamford CT 06907-0047
JJ
TEL: (203) 359-1660JJ
FAX: (203) 359-7700
JJ
e-mail: [email protected]
Canada:7
J
976 Bergar
JJ
Laval (Quebec) H7L 5A1
JJ
TEL: (514) 856-6928JJ
FAX: (514) 856-6886
JJ
e-mail: [email protected]
For immediate technical or application assistance:
USA and Canada:
J Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
JJ
Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
JJ
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
Mexico and
J
TEL: (001)800-TC-OMEGA
®
J
FAX: (001) 203-359-7807
Latin American:
J
En Español: (001) 203-359-7803J
JJ
e-mail: [email protected]
Servicing Europe:
Czech Republic:
J
Frystatska 184, 733 01 Karviná
JJ
TEL: +420 59 6311899JJ
FAX: +420 59 6311114
JJ
e-mail: [email protected]
Germany/Austria:
J Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
JJ
TEL: +49 7056 9398-0JJ
FAX: +49 7056 9398-29
JJ
Toll Free in Germany: 0800 639 7678
JJ
e-mail: [email protected]
United Kingdom:
J One Omega Drive
ISO 9002 Certified
J
River Bend Technology Centre
JJ
Northbank, Irlam Manchester M44 5BD United Kingdom
JJ
TEL: +44 161 777 6611J FAX: +44 161 777 6622
JJ
Toll Free in England: 0800 488 488
JJ
e-mail: [email protected]
OMEGAnet
®
On-Line Service
www.omega.com
Internet e-mail
®
®
5
6
To Configure Meter Inputs:
1.
Press MENU until the meter displays:
2.
Press
/MIN to display:
3.
Press
/MAX, if necessary to change the configuration value.
4.
Repeat steps 2 and 3 for
I
IN
NP
P..2
2
through
I
IN
NP
P..7
7
5.
Press MENU
The meter displays:
To Set Decimal Point Position:
1.
Press MENU until the meter displays:
2.
Press
/MIN to display:
Press
/MAX to move the decimal point
to the desired location.
3.
Press MENU.
The meter displays:
4.
Press RESET twice. The meter flashes and
displays an output reading.
The meter is now in RUN mode.
Configure Reading Offset
Now that you are in the run mode with a transducer connected to
the meter, do the following:
1.
Simulate a load on the transducer (leave the pressure port
open).
2.
Note the display reading. Let’s assume the display shows
43.5
3.
To make the display show zeroes, press MENU
until the meter displays:
4.
Press
/MIN to display the previous reading offset value.
5.
Using
/MIN to scroll through the digits and
/MAX to change the value, enter the value
-0043.5
Configure Reading Offset (continued)
6.
Press MENU.
The meter displays:
7.
Press RESET twice.
The meter flashes and then displays a value.
Your meter is now in RUN mode and operational.
If You Have Bipolar Input ±50mV
The typical setting for your meter is unipolar. If, however, you
have bipolar input ±50mV, you must install jumper S1B. Remove
the outer panel mounting sleeve to expose the jumper.
S1 Jumper Location on Signal Input Board
In addition, you must set configuration menu value INP.3=1 (under
IN CNF menu). Refer to the Configuration sections of this Quick
Start manual.
A
B
A
D
G
H
V
L
P
S
T
U
B
C
E
F
J
K
N
M
R
Q
S2
J3
J9
S1
SETPTS
/MIN
MENU
RESET
/MAX
DeC pt
SETPTS
/MIN
MENU
RESET
/MAX
FFFF.FF
SETPTS
/MIN
MENU
RESET
/MAX
stored
SETPTS
/MIN
MENU
RESET
/MAX
cntby
SETPTS
/MIN
MENU
RESET
/MAX
reset2
SETPTS
/MIN
MENU
RESET
/MAX
reset2
SETPTS
/MIN
MENU
RESET
/MAX
rdg of
SETPTS
/MIN
MENU
RESET
/MAX
-0043.5
SETPTS
/MIN
MENU
RESET
/MAX
in cnf
SETPTS
/MIN
MENU
RESET
/MAX
stored
SETPTS
/MIN
MENU
RESET
/MAX
inp.1=0
SETPTS
/MIN
MENU
RESET
/MAX
in cnf
SETPTS
/MIN
MENU
RESET
/MAX
stored
SETPTS
/MIN
MENU
RESET
/MAX
in.sc.of