Flue pipe installation
10
27
We reserve the right to make any changes due to technical modifications.
Installation and maintenance instructions Logano G124X II/SP special gas-fired boiler • Issue 04/2005
Installing electrical connection of vent damper
5.
Disconnect your heating system from the mains
electricity supply.
6.
Route the connection wiring of the vent baffle
through the wiring retainer behind the boiler and
between the insulation and the jacket to the aquastat
on the front of the boiler.
7.
Connect vent damper to the terminal plug on
aquastat as shown in the circuit diagram.
Fig. 24
Connecting vent damper (G124X II left, G124X SP
right)
1
Terminal plug on aquastat
2
Aquastat
1
2
1
2
USER NOTE
All connection points on the complete
venting system must be checked for
correct installation and sealing
immediately after carrying out one of the
installation steps. The seams and
connections must be checked for gas
leaks. Regulations require the complete
flue system to be checked at least once a
year by a qualified technician after
installation and initial operation.