Additional programming options
8
Logamatic 4121, 4122 and 4126 - Subject to technical modifications.
59
8.1.3 Deleting a heating phase
A heating phase consists of two switching points - a start and a stop point.
If you wish to delete a heating phase, both switching points must be deleted.
Example:
In the "Midday program" for heating circuit 2, you want to delete the Monday
heating phase from 11:30 h to 13:00 h to create one single heating pause
from 08:00 h to 17:00 h.
Your modified program will be saved under the program name "Own" and
the number of the heating circuit.
z
Select a heating circuit (
Æ
Chapter 7.6).
Example: Heating circ. 2
z
Select the standard program for the chosen heating circuit (
Æ
Chapter 7.10).
Example: "Midday program"
The first switching point (start point): "Monday at 06:00" at "21°C" will be
displayed. The displayed temperature depends on the set room temperature.
AUT
Fig. 17
Deleting a heating phase
A
"Midday program"
B
New program "Own program 2"
1
Day mode
2
Night mode
3
Delete
A
B
7 747 012 053-12.1RS
1
2
06:00
22:00
1
2
08:00 11:30 13:00 17:00
06:00 08:00
22:00
17:00
3
Midday program
21°C
at 06:00
Monday