Operation
ULTRAFEEDER
- 3-9 -
P1 Programming Level
LFA m/min
Î
ADVANCED
Î
MENU P1
The P1 programming level allows you to setup 4 parameters:
1)
Device main tension;
2)
Tolerance with respect to the main tension;
3)
Max deviation time from tolerance band;
4)
Increment/Decrement resolution of graduated tension.
With the ULTRAFEEDER in
CONTROL
status,
(LFA nnnn displayed on LCD)
press
and hold it down for 3 seconds.
The display will show the
ADVANCED
label and the ULTRAFEEDER will switch
to PROGRAM status.
or
to continue.
to start programming of parameters belonging to P1 menu.
P1.1
MAIN TENSION
Tension value with which the ULTRAFEEDER device must operate to create the
desired article.
[Allowed values 0.2 ÷ 100.0 grams].
Choose the desired value using:
(to increase the value)
or
(to decrease the value).
to confirm.
P1.2
ERROR TENSION
Tolerance band beyond which the machine will be stopped. The error indication
and machine stop occur only if such tolerance is exceeded for the time period set in
the next parameter
(
TIME ALARM
).
[Allowed values ± 0.0
(*)
÷ 99.5 grams (with automatic limitation to 0.4 grams for
what concerns the negative tolerance, if the tension is greater than 0.5 gr.,
otherwise it is automatically stepped down)].
(*)
Setting
0.0 activates the AUTO mode; this means that the system will
automatically calculate the error threshold as 50% of
MAIN TENSION
. This
means that when changing the
MAIN TENSION
. (P1.1) value, the
ERROR TENSION
value changes accordingly, without the need of changing it manually.
Choose the desired value using:
(to increase the value)
or
(to decrease the value).
to confirm.
Summary of Contents for ULTRAFEEDER
Page 1: ...ULTRAFEEDER YARN CONTROL SYSTEM Operating Manual ENGLISH Rev 4 1 February 2017 ...
Page 40: ...Technical Data and Installation 2 28 ULTRAFEEDER Page intentionally left blank ...
Page 72: ...ULTRAFEEDER Troubleshooting and Maintenance 4 6 ULTRAFEEDER Page intentionally left blank ...
Page 78: ...YTT Device 5 6 ULTRAFEEDER Page intentionally left blank ...