Style Programming (MTC)
SMART MATRIX MTC
2 - 32
RESET AUTO
: This function allows you to choose
the counter reset mode: i.e. whether the counter will
be automatically reset when reaching the Target, or it
will have to be manually reset by the operator.
ON
:
When reaching the TARGET, the counter is
automatically reset by the next stroke. This is the
mode typically used on automatic machines. The
sensor continues to count the strokes until it detects
a machine steady condition (no more strokes). When
the sensor detects a new stroke, it resets the counter
and starts again the count.
OFF
:
When reaching the
TARGET, both LEDs (red and green) on the sensor,
start blinking.
To reset the counter the operator must skim for
about
one second
the Touch Light. The red led on
and green led off condition indicates that the reset
occurred successfully. The 1 second time is needed
to avoid an undesired counter reset due to
accidental contacts with the sensor. After having
reached the TARGET, the counter will still be
incremented if further strokes occur.
EXT RESET:
This function allows you to temporary
stop the meter count, by connecting to ground the
STOP output. The function may be either enabled
(
ON
) or disabled (
OFF
), however it will be effective
only if the STOP output is configured as Normally
Open contact.
SAVE
to save the set parameters and move to the
STYLE NAME
setting screen
Set the Style Name (
es.
MTC4
), operating as
described on paragraph - Navigation throughout the
Display Windows.
Once you have setup the Style Name.
If the set name was already used for another style,
the warning “
DOUBLE STYLE NAME
!” appears
YES
to save the style (
MTC4
) to the database.
Summary of Contents for SMART MATRIX MTC
Page 1: ...SMART MATRIX MTC Operating Manual ENGLISH Rev 1 0 September 2010 ...
Page 3: ...Introduction i ...
Page 4: ......
Page 9: ...Connections and Electrical Interface 1 ...
Page 10: ......
Page 17: ...Operating Instructions 2 ...
Page 18: ......
Page 71: ...System Information 3 ...
Page 72: ......