Sensor Configuration and Numbering
SMART MATRIX MTC
2 - 10
•
Point and select
MACHINE SIDES
.
•
Set the number of machine sides (
A corresponds to 1,
AB to 2, ABC to 3 and ABCD to 4
).
•
Point and select
SECTIONS PER SIDE
. Set the
number of sections per side.
•
Point and select
DEV. PER SECTION
(
e.g. 06
)(*).
To confirm the set values.
SAVE
to save the settings and startup the numbering
procedure.
•
The example shown indicates that the numbering
(identification) procedure of the 6 configured sensors is
going to begin.
•
The display of SM-DIN Boards will show
•
The green led will flash on all sensors
•
Shim the touch light of the sensor corresponding to
SIDE: A
,
SECT.: 01
,
DEVICE: 01
.
The sensor’s led changes from flashing green to red.
•
On SMART MATRIX display, the
DEVICE, SECTION
and
SIDE
fields will automatically increase to select one-
by-one the sensors to be numbered
•
Shim the touch light of the relevant sensor and continue
with the numbering of all sensors.
At the end of the numbering operation, the configuration
menu will re-appear.
To return to
SETUP
menu
(*)The totale number of configured devices (
MACHINE SIDES
x
SECTIONS PER SIDE
x
DEV. PER
SECTION
) must match the total number of devices previously set on
BOARDS CONFIGURATION
screen.
Otherwise a “
DEVICE NUMBER MISMATCH
” error message will appear”
Summary of Contents for SMART MATRIX MTC
Page 1: ...SMART MATRIX MTC Operating Manual ENGLISH Rev 1 0 September 2010 ...
Page 3: ...Introduction i ...
Page 4: ......
Page 9: ...Connections and Electrical Interface 1 ...
Page 10: ......
Page 17: ...Operating Instructions 2 ...
Page 18: ......
Page 71: ...System Information 3 ...
Page 72: ......