BSS Audio
DPR-402 User Manual v3.0
Page 20
14 Operation and Applications
14
.1 Compression
Barrier strip linking B-C and D-G (as factory set).
Initial settings.
Controls
Position
MODE SWITCH
Compress
THRESHOLD
Out
RATIO
4
ATTACK
-
RELEASE
Auto
GAIN
0dB
CHN BYPASS
In (Illuminated)
DE-ESS THRSHLD Out
FREQ
-
PK LIM THRSHLD Out
Rotate the THRESHOLD control anticlockwise until the BELOW THRESHOLD
meter is fully illuminated and an appropriate amount of gain is indicated on the
GAIN REDUCTION meter. This operation will be accompanied with a drop in
output level, as indicated by the OUTPUT METER. The output GAIN CONTROL
should now be adjusted to reinstate the output level. The levels of the
uncompressed input signal and the compressed output signal can now be
compared on the output meter by operating the METER INPUT switch.
Final adjustments of the controls can then be made to suit particular requirements,
including the RATIO, ATTACK, and RELEASE controls. The 'auto' position of the
release control provides for a program related operation of the dynamics of the
unit, and will be accepted for most general purpose applications. Should a tighter
or looser requirement be necessary, then both the attack and release controls can
be set individually to suit.
The experienced engineer will be able to set the compressor controls to near
optimum position for any source material with the BYPASS switch out, so that the
compressor can be 'dropped' into a live performance without disturbance.
14
.2 De-essing
The
DPR-402
has three modes of de-essing available, de-ess wide with
simultaneous compression, de-ess wide with full dynamic control, and de-ess HF