BSS Audio
DPR-402 User Manual v3.0
Page 32
Bypasses all functions of the unit at unity gain, allowing
all parameters to be adjusted and levels checked whilst
'on air'.
Momentarily connects the control side chain to the
output of the unit to allow monitoring of control insert
return.
Momentarily connects the input signal to the output
level meter to allow comparison of input and output
levels prior to operating the bypass switch.
Metering:
BELOW THRESHOLD: 5 LEDs to indicate side chain
level from 18dB to 0dB ref the set threshold.
GAIN REDUCTION: 9 LEDs to indicate the amount of
gain reduction from 3dV to 27dB. Display 'bright-up' at
30dB of reduction.
OUTPUT: 12 LEDs to indicate output level from -
24dBm to +18dBm. Display 'bright-up' at +21dBm
(clip).
DE-ESS: 2 LEDs to indicate normal and hard de-essing.
PEAK LIMITING: 2 LEDs to indicate normal and hard
peak limiting.
Stereo Switch
Couples channel 1 and channel 2 control signals for
(Rear Panel):
stereo operation. Indicated on the front panel by an
LED.
Rear Connections:
INPUT: XLR 3-31 or equivalent (Balanced)
OUTPUT: XLR 3-32 or equivalent (Unbalanced)
ACCESS POINTS: Barrier strip, providing control and
subtract side chain insertion points including HP and
LP filter sends, pre-emphasis and de-emphasis network
sends; inverse phase sends for expander mode; and
control side chain DC access point for stereo, quad
etc., coupling and gating.
Power:
Switch selectable 120V or 240V, 50/60Hz, 15VA. AC
fuses on the rear of the unit. DC fuses located inside the
unit.
Mounting requirements:
(Ht x W x D)
44.5mm x 483mm x 229mm
1U/1¾" x 19 x 9"
Weight:
4.5kg (Packed)