24
installed during electric heater selection. The system will treat the hot
water coil as either auxiliary heat in a heat pump application, or the sole
heat source. Setup options for Hydronic Heat applications are described
in the setup section of this instruction.
NOTE:
The daily airflow verification test will take place even when the
radiant hydronic heat option is selected.
5.5. Searching for SAM Module (If Applicable)
“Searching for SAM Module” will appear on the screen to determine if a
System Access Module, used for home automation only, is connected to
the system.
The SYSTXBBSAM01 is not compatible with this control. The
compatible modules are SYSTXNNRCT01. The SAM is used for home
automation purposes and is NOT used to connect the system control to
the Internet. The Evolution Connex Control must have at least Version 8
software or newer to be compatible with the SAM.
NOTE:
For more information regarding the SAM Module, reference the
latest version of the application specification entitled “SAM Remote
Access Application Specification, ASCII Protocol Information”,
available on HVACpartners.com, or the System Access Module
Installation Instructions.
A13117