Advanced Installation and Configuration Instructions

Table of Contents

Safety Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

How to use this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Hardware Differences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Print Label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Start-Up –> Dehum for Fan Coil or Furnace . . . . . . . . . . . . . . . . . . . . 10

Safety Considerations

Read  and  follow  manufacturer  instructions  carefully.  Follow  all  local

electrical codes during installation. All wiring must conform to local and

national  electrical codes.  Improper  wiring  or  installation may  damage

Thermostat. 
Recognize safety information. This is the safety-alert symbol  . When

you see this symbol on the equipment and in the instruction manual, be

alert to the potential for personal injury.
Understand  the  signal  words  DANGER, WARNING,  and  CAUTION.

These words are used with the safety-alert symbol. DANGER identifies

the most serious hazards which will result in severe personal injury or

death.  WARNING  signifies  a  hazard  which  could  result  in  personal

injury  or  death.  CAUTION  is  used  to  identify  unsafe  practices  which

may  result  in  minor  personal  injury  or  product  and  property  damage.

NOTE  is  used  to  highlight  suggestions  which  will  result  in  enhanced

installation, reliability, or operation.

Introduction

The  ecobee  Smart  Thermostat  Pro  with  voice  control,  Powered  by

Bryant  and  the  ecobee3  lite  Pro,  Powered  by  Bryant  provides  your

customers  with  freedom  and  flexibility  to  manage  their  home

environment. These thermostats help homeowners conserve energy, save

money and reduce their environmental impact. They support a furnace

with  AC  and  up  to  2-stages  of  heat.  For  heat  pumps  (air  to  air  or

Geothermal) they support up to four stages of heat (2-stage heat pump,

2-stage  auxiliary  heat)  and  two  stages  of  cool.  For  these  systems  the

thermostats  can  control  a  single  accessory,  such  as  a  humidifier,

dehumidifier,  ventilator,  HRV  or  ERV.  Also,  the  thermostats  can  be

installed  with  the  PEK  if  a  C  wire  isn't  present.  Additionally,  the

thermostats can control boilers with or without an AC. When connected

to a boiler, the thermostats support up to 2-stage of heat and 2-stages of

cool  and  a  single  accessory,  such  as  a  humidifier,  dehumidifier,

ventilator,  HRV  or  ERV.  When  used  with  a  boiler  they  cannot  be

installed with the PEK if a C wire isn't present, the C wire must come

from the air handler, not the boiler.

How to use this document

The advanced installation and configuration instructions are intended to

supplement  the  standard  installation  instructions  shipped  with  the

thermostat or available for download on www.HVACpartners.com. The

advanced settings and  configuration options  detailed  in  this document

are intended for professional installers only. Incorrect configuration may

lead to improper operation and equipment damage.
Each section of this document is outlined in the following structure:

Section Title

Location of this section within the thermostat menus.
Image showing available features in this section on the thermostat.

Feature Title

Feature Description

• Default Configuration

• Configuration Options
Image showing screen on the thermostat

EB-STATE3LTBB-01, EB-STATE3LTBR-01, 

EB-STATE5BB-01, EB-STATE5BR-01

A200491

ecobee Smart Thermostat Pro with voice control, Powered by Bryant

A200492

ecobee3 lite Pro, Powered by Bryant

WARNING

!

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury or death. 

Before  installing,  modifying,  or  servicing  system,  main  electrical

disconnect switch must be in the off position. There may be more than

1 disconnect switch. Lock out and tag switch with a suitable warning

label.

CAUTION

!

ELECTRICAL OPERATION HAZARD

Failure  to  follow  this  caution  may  result  in  equipment  damage  or

improper operation.
Improper wiring or installation may damage the thermostat. Check to

make  sure  wiring  is  connect  before  proceeding  with  installation  or

turning on unit.

Summary of Contents for EB-STATE3LTBB-01

Page 1: ...or ERV Also the thermostats can be installed with the PEK if a C wire isn t present Additionally the thermostats can control boilers with or without an AC When connected to a boiler the thermostats s...

Page 2: ...ntify the final assembly number model name country of origin and device serial number A210086 The following final assembly numbers and corresponding model name are as follows c Table 1 Final Assembly...

Page 3: ...mostat can control the equipment it is preferred to allow the Bryant equipment to determine the staging by not connecting W2 See furnace installation instructions for heat staging setup Power Extender...

Page 4: ...dd a Wire Kit works similar to the PEK Normally this would not be needed because the PEK comes with the ecobee However the PEK is limited to one extra wire and only one PEK can be used per system Seve...

Page 5: ...g valve During the startup process the O B should be configured to act as an O terminal with Bryant equipment since the equipment defaults to heating and needs the reversing valve to be energized on a...

Page 6: ...ion and Configuration Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 6 Air Conditioner with Boiler A200461 Boiler...

Page 7: ...bee PEK Venstar Add a Wire or Fast Stat Wiring Extender accessories mentioned above cannot be used The W call gets piggy backed on the common wire with the small black sender module installed at the t...

Page 8: ...ct variable speed furnaces The ACC terminal will wire to the DH or DHUM terminal on the equipment in these applications On the FV fan coils remove jumper J1 from the Easy Select board to enable this f...

Page 9: ...mer and so only Rc is connected It is important to note that in these applications Rc must be used instead of Rh like some Bryant thermostats If the heating and cooling equipment have separate transfo...

Page 10: ...made here Start Up Dehum for Fan Coil or Furnace Initial Start Up Wiring Standard A200469 During installation the thermostat will automatically detect which terminals have wires connected If something...

Page 11: ...entilator Initial Start Up Wiring Accessory Dehumidifier for Fancoil or Furnace A200471 When selecting dehumidifier for using the equipment s DHUM or DH terminal select the appropriate relay action A...

Page 12: ...e auxiliary heat is electric resistance then shut off the compressor when either a The manufacturer has a published lowest operating temperature for example our 5 stage inverters can only run down to...

Page 13: ...y the fan on a W1 allowing the heat exchanger to warm up before engaging airflow so the occupants do not get a blast of cold air This setting only affects the gas heat startup sequence it will not del...

Page 14: ...latent capacity of the evaporator coil while reducing sensible capacity Installation Settings Thresholds Cool Dissipation A200478 Cool Dissipation Time is default on but the feature should only be us...

Page 15: ...to 76 degrees the 2nd stage will come on Then both will run together until the room temperature is satisfied at 74 Reverse staging works example If there is a 74 degree cooling setpoint the 1st stage...

Page 16: ...200482 The Auxiliary Heat Maximum Outdoor Temperature specifies when the heat pump should be able to handle the heating load solo without the need for auxiliary electric heat to assist Aux heat will b...

Page 17: ...the thermostat the maximum difference allowed between the thermostat and hottest or coldest rooms in the home If a sensor measures a temperature that is significantly outside of this range it probabl...

Page 18: ...and the sensor stops detecting occupancy the thermostat s temperature data is gradually and not immediately removed from the calculation A200488 Each sensor can be used with a Comfort Setting Home Aw...

Page 19: ...nd without obligations 19 Training My Learning Center is your central location for professional residential HVAC training resources that help strengthen careers and businesses We believe in providing...

Page 20: ...pany Edition Date 04 21 Catalog No II EBSTATE 02 Replaces II EBSTATE 01 Advanced Installation and Configuration Instructions Manufacturer reserves the right to change at any time specifications and de...

Reviews: