Configuration Menu

To enter into the setting menu please follow the steps below: 

Step 1

, Turn the thermostat off by pressing               ;      

 

Step 2

, Press   

             

 

 , you will then see menu 1. At this step, if you press and hold “MENU”, you will access to MENU 4 directly.    

Step 3

, Use the up and down arrows to adjust the “sensor selection” which is Menu 1(Air sensing, Air and Floor, or Floor only)

Step 4

, Press   

           

    to move to the next Menu and once you have all the menu options set,

Setp 5

, Press   

                

   to accept and store.

Menu #  Feature

Explanation 

Adjustment

press up & down buttons to adjust

1

Mode/Sensor selection  

This thermostat is a combination model which allows you to 

choose 3 different modes.

A mode=Air Sensing Only(Has built in sensor)

AF mode=Air & Floor sensing(Floor probe must be installed)

F mode=Floor Sensing(Floor probe must be installed)     

A, AF, F (F by default) 

2

3

4

Maximum Floor Temp

( AF mode only)

This is to protect the floor surface.

20 °C~ 40 °C (28 °C by default)

5+2 / 7 Day Mode 

This allows you to program either 5 days at once, then the 2 

days of the weekend separately, or a full 7 days at the same

time or 7 days separately    

01 = 5+2 day programmable

02 = 7 day programmable(by default)

NEXT

MENU 

DONE 

Power on Your Thermostat

Then press                     button to turn on/off the thermostat. When your thermostat is turned off, the LCD will display OFF. 

When your thermostat is first connected to mains power, wait for about 30 seconds until the touch pad has self-adjusted. 

POWER 

POWER 

Reset

This allows you to reset your thermostat to factory default

Press and hold the down button until you see RES on screen

LCD symbols

Symbol

Event 

The buttons are locked 

Heating is turned on 

Program number

Set temperature

Symbol

AUTO 

Er 

Automatic mode,

executes the programmed schedules  

Event 

Temporary temperature override   

Increase 

The floor sensor is not being read by the thermostat 

OVERRIDE

Decrease

Manual mode  

1,2,3,4