Initial Start-Up –> Furnace
A200475
The fan should be controlled by the furnace for all current CBP and ICP furnaces. This allows the furnace to delay the fan on a W1 allowing the heat
exchanger to warm-up before engaging airflow so the occupants do not get a blast of cold air. This setting only affects the gas heat startup sequence, it
will not delay continuous fan or ventilation schedules, etc.
Initial Start-Up –> Humidifier
A200476
Typically, Steam should be selected as the humidifier choice even when an evaporative humidifier is installed. The ONLY difference between the two
choices is that steam provides the option to humidify with fan. There are no other differences.