: Advanced Installation and Configuration Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
8
Dehumidification with DH or DEHUM Terminal (FV Fan Coil and Variable Speed Furnaces)
A200464
If the accessory terminals are not being used for a humidifier or whole house dehumidifier, then they may be used for the dehumidification feature
integrated into Bryant FV fan coils and select variable speed furnaces. The ACC+ terminal will wire to the DH or DHUM terminal on the equipment in
these applications.
On the FV fan coils, remove jumper J1 from the Easy Select board to enable this feature.
Please also note that the equipment is expecting DH or DHUM to be energized during normal operation and DE-ENERGIZED on a dehumidification
call from the thermostat. It is a reverse logic input, as compared to Y, G, W, etc.
Initial Start-Up
A200465
When the thermostat is first powered up, or after resetting the stat, a bee will be buzzing around the screen. This will be followed by the start of the
initial configuration.
Easy Select Terminal on FV Fan Coil