Technical data
and start-up
BDC546
48
8
Connections
8.1
Control connector
NOTICE
The control connector has been designed for a maximum number of 10 cycles of connector
operation! The manufacturer guarantees the full functioning (conductance, tightness) up to this
quantity.
For a professional mounting of the AMPSEAL contacts SN/LP, we recommend the usage of the
following crimping tool:
Tyco 58440-1
INFORMATION
Control connectors included in the scope of delivery are to be converted in accordance with the
respective requirements (EMC, environmental impacts etc.). Here, only the actually used pins are to
be wired (mandatory* or highly recommended**).
Pin 16
EN
is to be connected to pin 2
AUX
via a switch (e.g.: in the vehicle by means of the ignition
key with the Plus wiring system).
1.
GND *
Signal ground
(Minus wiring system, terminal 31)
2.
AUX *
+12 V
(Plus wiring system, terminal 30)
3.
NC
4.
NC
5.
NC
6.
TXD **
RS232 Transmit (9 pole D-Sub: pin 2)
7.
RXD **
RS232 Receive (9 pole D-Sub: pin 3)
8.
P_GND
**
RS232 ground (9 pole D-Sub: pin 5)
9.
CNL *
CAN low
10.
CNH *
CAN high
11.
12.
13.
PRO **
Enable firmware download
14.
PFO_VC-
15.
PFI_VC-
16.
EN *
Enable (power ON, terminal 15)
17.
DO_MC
18.
NC
19.
IL **
HV interlock input
20.
NC
21.
NC
22.
NC
23.
NC
Summary of Contents for BDC546
Page 27: ...27 Technical data and start up BDC546 6 6 Vehicle installation basic principle ...
Page 82: ...Technical data and start up BDC546 82 16 Attachments 16 1 Cable fitting ...
Page 83: ...83 Technical data and start up BDC546 ...
Page 84: ...Technical data and start up BDC546 84 ...
Page 85: ...85 Technical data and start up BDC546 ...
Page 86: ...Technical data and start up BDC546 86 16 2 Cable lugs ...