Technical data
and start-up
BDC546
54
PROCEDURE STEP
ILLUSTRATION / OTHER INFORMATION
7.
Connect the control connector (1) to the device.
Manually check if the control connector (1) is
secure!
Always ensure suitable mounting of the required
strain relief elements!
8.
Connect the cooling water hoses.
Refer to chapter
Always check for correct connection of the
cooling water inlet (1) and cooling water
outlet (2)!
9.
Manually check that all cable and hose connections
are tightly secured.
All cable connections near the device must be
secured with a strain relief in order to protect the
cable against vibration and consequential
damage.
---
10.
Ventilate the cooling system.
Ensure that no air is trapped in the cooling
system!
Refer to chapter
---
11.
Ensure that the converter is connected to the power
source via a suitable pre-charging unit.
Refer to chapter
Any connection without pre-charging contactor
may lead to voltage peaks and damage to the
charger!
---
INFORMATION
The device is now completely installed and can be commissioned. The device can be set by means
of customer-specific CAN tools or using the BRUSA-specific
PARAM
software. This software is
ideally suited for the device and can be purchased optionally. For further information, please contact
the manufacturer under the address provided in chapter
Summary of Contents for BDC546
Page 27: ...27 Technical data and start up BDC546 6 6 Vehicle installation basic principle ...
Page 82: ...Technical data and start up BDC546 82 16 Attachments 16 1 Cable fitting ...
Page 83: ...83 Technical data and start up BDC546 ...
Page 84: ...Technical data and start up BDC546 84 ...
Page 85: ...85 Technical data and start up BDC546 ...
Page 86: ...Technical data and start up BDC546 86 16 2 Cable lugs ...