Technical data
and start-up
BDC546
64
10.2.2 Parameter groups
NUMBER
PARAMETER GROUP
DESCRIPTION
01
CAN configuration - CRC
In this category, the CAN Ids for the various messages required for
communication between the device and superordinate control systems
are defined (e.g.: vehicle control unit, CVI, PARAM, etc.)
The messages are separated into messages that are sent by the control
system to the device and messages that are returned by the device to
the system.
02
Device configuration - CRC
These parameters are used to calibrate the device. This way, the
voltage and current values of the device as well as the efficiency are
optimally coordinated.
These parameters are set by BRUSA and cannot be changed by the
customer.
In this category, users can define the thresholds of the limiting voltage
and current controller. Respectively, the same limits can be set via CAN
as well as via PARAM. The controller prefers always the value that is
set “closer”, i.e. applies first.
03
FPGA ULS controller
configuration - CRC
Configuration by BRUSA, content not relevant for the customer
04
FPGA UHS controller
configuration - CRC
05
FPGA IHS controller
configuration - CRC
Configuration by BRUSA, content not relevant for the customer
06
FPGA ILS controller
configuration - CRC
Configuration by BRUSA, content not relevant for the customer
07
FPGA HR NVM data - CRC
Configuration by BRUSA, content not relevant for the customer
08
FPGA BR NVM data - CRC
Configuration by BRUSA, content not relevant for the customer
09
FW gains, offset - CRC
Configuration by BRUSA, content not relevant for the customer
0A
FPGA gains, offsets and
settings - CRC
Configuration by BRUSA, content not relevant for the customer
10
Digital IO
Device-internal signals, content not relevant for the customer
11
Analogue input
Device-internal signals, content not relevant for the customer
12
Analogue values calculated and
offsets
Measuring values of analogue signals like the internal 15 V supply,
redundant UHS/ULS measurements and resistor values of the pyrofuse.
13
PWM input
Contains the measured frequency and the duty cycle of the active
interlock signal.
20
Status
Different bitmaps and states for BRUSA support.
21
FPGA error history
Content not relevant for the customer
22
Temperatures
In this category, the currently measured temperatures of the modules
and main chokes in the device are displayed.
23
Stored App Data
In this category, the measured minimum and maximum temperatures
are listed. If required, the recorded extreme values can be deleted.
30
stInit
Contains information on the used module versions, content not relevant
for the customer
31
General parameters
In this category, the serial number as well as the operating hours of the
device are provided.
Summary of Contents for BDC546
Page 27: ...27 Technical data and start up BDC546 6 6 Vehicle installation basic principle ...
Page 82: ...Technical data and start up BDC546 82 16 Attachments 16 1 Cable fitting ...
Page 83: ...83 Technical data and start up BDC546 ...
Page 84: ...Technical data and start up BDC546 84 ...
Page 85: ...85 Technical data and start up BDC546 ...
Page 86: ...Technical data and start up BDC546 86 16 2 Cable lugs ...