©2009,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®
SRE-1550 02-09-2009
36
UNIT DOES NOT
SHUT OFF WHEN IT
HITS THE BUMPER
AT THE END OF THE
RAIL
UNIT WILL NOT
OPERATE WITH
CALL / SEND
REMOTE
UNIT OPERATES
ERRATICALLY OR
INTERMITTENTLY
WITH A RIDER
USING THE
ARMREST-MOUNTED
CONTROL SWITCH
UNIT WILL NOT
OPERATE UNLESS
THE SEAT IS
POSITIONED SO THAT
IT FACES THE OPEN
SIDE OF THE STAIRS
• Check swivel seat safety switch.
• Check
that the footrest safety tray is not dragging on
the stair nosing or hitting debris on the stairs.
If necessary
, reposition the stair rail
mounting brackets to correct the problem.
• Check the rail
for debris that may contact safety
switches (footrest and carriage panels).
• This is corre
ct lift operation.
• A safety s
witch in the seat swivel prevents the unit
from operating with the seat "out of position".
• Check batte
ries in remote call/send unit.
• Aim tran
smiter at the carriage
• Transmitters must be `learned' to receiver.
• Connections w
ere not made correctly when changing
unit from left-side to right-side installation.
Consult wiring diagram in installation manual.
• Verify correct operation of limit switch in carriage
assembly.
• Wipe do
wn rail.
•
Apply a small amount of grease to the
gear rack
only
ROUGH OR
CHATTERING RIDE
TROUBLESHOOTING