19
©2009,1996 BRUNO INDEPENDENT LIVING AIDS, INC.®
SRE-1550 02-09-2009
• Shorten
the switch on
the
lower end
of the carriage.
The final limit switch and actuation ramp
assembly is safety features which
enhance the stopping capability of the
Elevator.
1. Mount the actuation ramp to the side
of the rail, 1" (25 mm) from the top of
the rail in a LEFT-HAND installation.
In a RIGHT-HAND installation mount
the ramp 8" (203 mm) from the top
end of the rail.
2. Tighten M6 X 10 hex head screws on
bottom of ramp.
3. The limit switches on the end of the
carriages require adjustment (see
illustration below).
FAILURE TO ADJUST LIMIT
SWITCHES WILL INTERFERE WITH
UNIT CHARGING .
FINAL LIMIT SWITCH AND ACTUATION RAMP
Residential and Commercial Units
INSTALLATION
tighten
M6 x 10 hex
head cap screws
Measure the distance
from the end of the
rail to the inside
edge of the actuation
ramp.
1" LH
8" RH
•
Lengthen
the switch on the
upper end
of the carriage.