Overheated message
During the burnup, the
message "Overheated"
appears
Reduce the wood feed quantity!
Check that the appliance setting has the
correct set of parameters. The error message
reset process is automatic as burnup proceeds
Self-test:
The throttle valve only
moves up and stays there.
Check the motor cable for breakages
Check settings in the Doorswitch menu
(must be set to "Auto")
In operation:
Throttle valve closes too
quickly, lack of air
Does the current parameter set match the
appliance?
Check the flue gas temperature display: are
the values displayed plausible?
Weak burnup (small flame) selected?
Check wiring of flue gas sensor for
impermissible extension with copper cable or
similar.
Check draught conditions
Check leak tightness of the appliance (viewing
panes, door, ash pan etc.).
In operation:
Throttle valve blade does
not
move to the 100% open
position after the firebox
door has been opened.
Check whether the "Door open" message is
shown on the display
Check the settings in the Doorswitch menu
(must be set to "Auto")
In operation:
The throttle vale does not
close all the way.
Mechanics sluggish, render passable Check
the parameter setting: does the current
parameter set match the device?
Check the valve mechanics for play