Electrical and Ignition
Charging System Tests
126
•
62 VAC at 300 RPM
Charging System Tests
The charging system provides 12 VDC for battery
charging. Alternator total output, or
GROSS
out-
put is:
•
10 A at 500 RPM
•
50 A from 2000 RPM to WOT.
Charging system available output to the battery, or
NET
output is shown in the following graph:
Use
Evinrude Diagnostics
software to monitor bat-
tery voltage and
GROSS
charge current.
Use an inductive amp meter to monitor
NET
charge current at the battery.
Fluke
†
,
Snap-On
†
or
various other digital meters should be available
through local tool suppliers.
1.
Stator Test Adapter
009360
1
Battery Charging Current (Net) @ 14 VDC
009339
Engine Monitor Screen
009242
1.
Main and auxiliary battery voltage display
2.
Main and auxiliary charge current display
1
2
Summary of Contents for E 250 L HO AG B