6. Operation
6.1 Power-on Utilities
There are various power-on utilities to set up and test the printer's functions.
Use power-on utilities to set sensor calibration, self-test, and factory default functions.
1. Turn off the label printer.
2. Press and hold the right
Selection
button, and then turn on the Power Switch.
3. Release the button when the function you want to set or test appears on the screen.
Power-On Utility
Power LED Patterns
LED color
Function
Amber
(Lit)
Red
(Blinks five
times)
Amber
(Blinks five
times)
Green
(Blinks five
times)
Green/
Amber
(Blinks five
times)
Red/
Amber
(Blinks five
times)
Green
(Lit)
1. Sensor Calibration (Gap /
black mark sensor)
2. Self-test (And enter Dump
Mode)
3. Factory Default
4. Bline Calibration
5. Gap Calibration
6. READY (Skip AUTO.BAS)