5. POWER SUPPLY EQUIPMENT
RH-981A
106
Lower thread trimmer OFF sensor
• The lower thread trimmer OFF sensor is attached to
the cylinder which drives the lower thread trimmer.
• The lower thread trimmer OFF sensor is intended to
make the lower thread trimmer securely set to off.
• If the lower thread trimmer OFF sensor is out of
control or attached incorrectly, its connectors are not
attached correctly, or the cord does not supply
electricity, error code E-15, E-45, or E-75 will appear.
Safety sensor
• The limit switch is attached to the front of the bed.
• The safety sensor is intended to check that the
machine head is positioned correctly for safe
operation.
• The safety sensor will be activated to stop all motions
when the machine head is raised during sewing.
• If the machine head is kept raised, the safety sensor
is out of control, its connectors are not attached
securely, or the cord does not flow electricity, error
code E-02, E-32, or E-62 will appear.
3542Q
Lower thread trimmer
OFF sensor
3543Q
Safety switch