5. POWER SUPPLY EQUIPMENT
RH-981A
94
3. Connectors to be attached to power supply circuit board
P1 [POWER] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. VHR-7N)
Pin no.
Signal name
Probable symptoms due to poor contact
1
+5V
2
+24V
3
0V
4
+55V
5
+55V
6
0V(P0V)
7
0V(P0V)
• Power does not come on.
• Feed bracket does not move.
• Machine operation becomes unstable.
• Home position can not be found.
• Error code E80 appears.
P2 [PER] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. PHR-5)
Pin no.
Signal name
Probable symptoms due to poor contact
1
Relay condition input
2
Primary voltage detect
3
Relay OFF output
4
+55V OFF output
5
0V
• One of error codes E26, E92, E98, and E99 appears.
P3 [DC18] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. PHR-11)
Pin no.
Signal name
Probable symptoms due to poor contact
1
+18V (A18V)
2
0V (A0V)
3
-
4
+18V (B18V)
5
0V (B0V)
6
-
7
+18V (C18V)
8
0V (C0V)
9
-
10
+18V (D18V)
11
0V (D0V)
• Machine motor does not run.
• Rotation of machine motor is not correct.
• Error code E70 or E91 appears.
P4 [ACIN] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. LP-04-2V)
Pin no.
Signal name
Probable symptoms due to poor contact
1
AC input
2
AC input
3
-
4
Ground
• Power does not come on.
• Machine operation becomes unstable.
• Error code E92 appears.
P5 [DC300] (MOLEX3191-02R1)
Pin no.
Signal name
Probable symptoms due to poor contact
1
0V (for machine motor)
2
+300V
• Machine motor does not run.
• Rotation of machine motor is not correct.
• Error code E70 or E91 appears.