![Brother RH-981A Service Manual Download Page 104](http://html.mh-extra.com/html/brother/rh-981a/rh-981a_service-manual_2819842104.webp)
5. POWER SUPPLY EQUIPMENT
RH-981A
96
5. Connectors to be attached to PMD PCB for
θ
axis
P1 [RPM] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. VHR-6N)
Pin no.
Signal name
Probable symptoms due to poor contact
1
θ
-axis PM driving current (RA)
2
θ
-axis PM driving current (RB)
3
θ
-axis PM driving current (RC)
4
θ
-axis PM driving current (RD)
5
θ
-axis PM driving current (RE)
6
-
• Needle bar motion is not correct.
•
θ
-axis home position can not be found.
• Error code E52 or E82 appears.
P2 [DC55] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. VHR-2N)
Pin no.
Signal name
Probable symptoms due to poor contact
1
+55V
2
0V (P0V)
• Feed bracket does not move.
• Home position can not be found.
• Error code E80 appears.
P3 [CONTROL] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. H8P-SHF-AA)
Pin no.
Signal name
Probable symptoms due to poor contact
1
θ
-axis PM clock signal
2
θ
-axis PM direction signal
3
θ
-axis PM save signal
4
θ
-axis PM excitation signal
5
+5V
6
+5V
7
0V
8
0V
• Needle bar motion is not correct.
•
θ
-axis home position can not be found.
• Error code E52 or E82 appears.