Confidential
2-12
Error
Code
Contents
Refer to
page:
2A00
No black ink cartridge loaded.
- Detected by the ink cartridge detection sensor.
2A01
No yellow ink cartridge loaded.
- Detected by the ink cartridge detection sensor.
2A02
No cyan ink cartridge loaded.
- Detected by the ink cartridge detection sensor.
2A03
No magenta ink cartridge loaded.
- Detected by the ink cartridge detection sensor.
2B00
Black ink cartridge ink remaining counter error
2B01
Yellow ink cartridge ink remaining counter error
2B02
Cyan ink cartridge ink remaining counter error
2B03
Magenta ink cartridge ink remaining counter error
2E00
Cannot communicate with ink cartridge IC chip (machine body side.)
2F00
Ink cartridge cover sensor detects opened cover state.
3000
Carriage does not move.
- Detected by the CR encoder sensor.
3100
Carriage cannot detect origin.
- Detected by the CR encoder sensor.
3200
Head capping is unable.
3500
Abnormal stop of head/carriage unit being driven
- Causes other than paper jam when ink is not discharging
3800
Abnormal stop of head/carriage unit being driven
- Caused by paper jam when ink is not discharging
3B00
Abnormal stop of head/carriage unit being driven
- Causes other than paper jam when ink is discharging
3C00
Abnormal stop of head/carriage unit being driven
- Caused by paper jam when ink is discharging
3E00
Defective occurs in the ASF motor, carriage motor or paper feed motor.
3F00
Carriage motor cannot stop.
4000
Casing internal thermistor defective
- Casing internal thermistor detects -20 degree-C or less, or 80 degree-C
or more when power is ON.
4200
Head voltage does not turn OFF.
4300
Head thermistor defective
- Head thermistor detects -20 degree-C or less, or 80 degree-C or more
when power is ON.
4400
Head driver IC detects abnormal temperature during operation or stand-by.
4600
Purge count or flushing count overflown.
4800
Head flat cable detected to be not correctly inserted.
4900
Head voltage does not raise.
4C00
ASIC thermistor error
- The ASIC thermistor detected a temperature of -21 degree-C or less, or
125 degree-C or greater, when the machine was turned on.