Confidential
2-27
■
Error Code 1700
Recording paper size error (duplex-printing/duplex-copying)
- Paper width is narrower than 95.5 mm (detection by paper width sensor)
- Paper length is longer than 461.8 mm (detection by registration sensor)
- Paper length is shorter than 143.5 mm (detection by registration sensor)
< User Check >
- Check whether the recording paper being used is within the specification.
- Check that dark recording paper is not used.
■
Error Code 1800
Paper jam during duplex-printing
- Registration sensor does not detect paper feed within specified pulse numbers in
the second side paper re-feed.
< User Check >
- Remove the jammed paper.
- Check whether the recording paper being used is within the specification.
- Check that recording paper are not curled, wrinkled or wet.
- Check that Output paper tray is set correctly (not inserted halfway)
.
Step
Cause
Solution
1
CR encoder strip stained
Clean the CR encoder strip.
2
PF encoder disk stained
Clean the PF encoder disk and flushing guide.
(refer to
"Precautions for Troubleshooting and/
3
Registration actuator caught
on the surrounding parts
Set the registration actuator into place.
4
Switchback actuator caught on
the surrounding parts
Set the switchback frame ASSY into place.
5
CR encoder strip defective
Replace the CR encoder strip.
6
PF encoder disk defective
Replace the PF encoder disk.
7
Registration sensor defective
Replace the registration sensor PCB.
8
Paper width sensor defective
Replace the carriage PCB ASSY.
9
Paper feed motor defective
Replace the paper feed motor.
10
Main PCB defective
Replace the main PCB.
Step
Cause
Solution
1
Foreign materials in the duplex
print paper path
Remove foreign materials.
2
Registration actuator caught
on the surrounding parts
Set the registration actuator into place.
3
Switchback actuator caught on
the surrounding parts
Set the switchback frame ASSY into place.
4
Registration sensor defective
Replace the registration sensor PCB.
5
Switchback roller defective
Replace the switchback roller.
6
Drive frame ASSY defective
Replace the maintenance unit.
7
Main PCB defective
Replace the main PCB.