App.1-2
Confidential
The functions and settings for each worker switch (WSW) are described below;
■
WSW47 (Switching between high-speed USB and full-speed USB)
■
WSW54 (PictBridge command delay time (HL-3070CW only))
- Selector 1 and 2: PictBridge command delay time (HL-3070CW only)
These selectors specify the PictBridge command delay time that applies when the machine
responds to the digital camera connected via PictBridge during negotiation. If the machine fails to
receive data from the digital camera, change the delay time.
Selector No.
Function
Setting and Specifications
1
|
7
Not used
8
Switching between high-speed
USB and full-speed USB
0: Auto switching between high-speed
USB (ver. 2.0) and full-speed USB
(ver. 1.1)
1: Fixed to full-speed USB (ver. 1.1)
Selector No.
Function
Setting and Specifications
1
2
PictBridge command delay time
(HL-3070CW only)
No. 1 2
0 0: 100 msec (default)
0 1: 0 msec
1 0: 50 msec
1 1: 200 msec
3
|
8
Not used
Summary of Contents for HL-3040CN
Page 10: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 33: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Page 61: ...2 27 Confidential Fig 2 27 Fuser center thermistor Fuser side thermistor Fuser unit Front ...
Page 63: ...Confidential CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Page 149: ...Confidential CHAPTER 4 PERIODICAL MAINTENANCE ...
Page 171: ...Confidential CHAPTER 5 DISASSEMBLY AND ASSEMBLY ...
Page 336: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 342: ...6 5 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...
Page 352: ...Confidential CHAPTER 7 SERVICE FUNCTIONS ...
Page 375: ...7 21 Confidential Color registration adjustment chart Fig 7 7 ...
Page 379: ...7 25 Confidential LED test pattern M68_L Fig 7 9 ...
Page 381: ...7 27 Confidential Fig 7 10 ...
Page 383: ...7 29 Confidential Color test pattern Fig 7 11 MCYK Y C M K YCMK_ _A ...
Page 408: ...Confidential CHAPTER 8 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 411: ...8 2 Confidential High voltage Power Supply PCB Circuit Diagram SYS HITEK SPH 8N35 2 3 ...
Page 412: ...8 3 Confidential High voltage Power Supply PCB Circuit Diagram SYS HITEK SPH 8N35 3 3 ...
Page 413: ...8 4 Confidential High voltage Power Supply PCB Circuit Diagram MURATA MPH3316 1 3 ...
Page 414: ...8 5 Confidential High voltage Power Supply PCB Circuit Diagram MURATA MPH3316 2 3 ...
Page 415: ...8 6 Confidential High voltage Power Supply PCB Circuit Diagram MURATA MPH3316 3 3 ...
Page 416: ...8 7 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 417: ...8 8 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 418: ...8 9 Confidential 2 WIRING DIAGRAM Wiring Diagram 1 2 ...
Page 419: ...8 10 Confidential Wiring Diagram 2 2 ...
Page 429: ...Confidential APPENDIX 3 SERIAL NUMBERING SYSTEM ...
Page 431: ...App 3 2 Confidential Serial number of the LED ASSY Print position Fig App 3 4 Serial number ...
Page 432: ...Confidential APPENDIX 4 SCREW CATALOGUE ...
Page 434: ...Confidential APPENDIX 5 REFERENCES ...
Page 436: ...Confidential APPENDIX 6 GLOSSARY ...