2-30
Confidential
Error code 58
Any of errors 6A to 6D, 6F, 76 or 78 occurred when the power was turned ON or the machine
goes back to the ready state from sleep mode.
Error code 59
Rechecking the error after the power switch was turned OFF and then ON again because an
error was detected by the center thermistor of the fuser unit.
(Displayed for approximately 15 minutes when the power was turned OFF and then ON
again after occurrence of error code 58)
Print Unable 58
Turn the power off and then back on again.
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
Cause
Remedy
1
Any fuser error occurs when
started in the ready state.
Follow the "Remedy" of the error code that has
reoccurred.
Self-Diagnostic
Will Automatically Restart within 15 minutes.
Step
Cause
Remedy
1
Connection failure of the center
thermistor harness of the fuser
unit
Reconnect the center thermistor harness of the
fuser unit.
2
Connection failure of the heater
harness of the fuser unit
Reconnect the heater harness of the fuser unit.
3
Connection failure of the eject
sensor PCB harness
Reconnect the eject sensor PCB harness.
4
Eject sensor PCB failure
Replace the eject sensor PCB ASSY.
5
Low voltage power supply PCB
failure
Replace the low voltage power supply PCB
ASSY.
6
Main PCB failure
Replace the main PCB ASSY.
7
Fuser unit failure
Replace the fuser unit.
CAUTION:
• Turn OFF the power switch once, and after checking that the fuser unit sufficiently
cools down, turn ON the power switch again and leave the machine for 10 minutes.
Then, this problem may be cleared.
Summary of Contents for FAX-2950
Page 20: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 35: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Page 45: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 ...
Page 122: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Page 130: ...3 6 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Page 136: ...3 12 Confidential 3 New toner sensor PCB ASSY New toner sensor PCB ASSY Main PCB ASSY Guide ...
Page 204: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Page 217: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 224: ...5 5 Confidential Black and white color scanning Fig 5 1 ...
Page 263: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Page 266: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 267: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL REPLACEMENT PARTS 7 1 ...
Page 269: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 273: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...
Page 275: ...Confidential APPENDIX 4 HOW TO MAKE PROTECTIVE MATERIAL FOR DRUM UNIT ...