2-14
Confidential
Error
codes
Description
Refer
to:
Error
codes
Description
Refer
to:
4F03
―
6200
―
4F04
―
6201
―
5001
―
6202
―
5002
―
6203
―
5003
―
6204
―
5004
―
6208
―
5005
―
6209
―
5100
―
620A
―
5200
―
6300
―
5301
―
6400
―
5302
―
6602
―
5401
―
6701
―
5402
―
6801
The side thermistor of the fuser unit or
the internal temperature sensor
detected a temperature higher than
the specified value.
5406
―
6802
―
5502
―
6901
An error occurred in the fuser unit
when the power switch was turned
ON or sleep mode was released.
5602
―
6902
Rechecking the error after the power
switch was turned OFF and then ON
again because an error was detected
in the fuser unit. (This message is
displayed for approximately 15
minutes when the machine is
restarted after error code 6901 has
occurred.)
5702
―
6A00
Detected discharge that may be
attributable to dirty corona wire on the
drum unit.
5801
―
6B01
―
5802
―
6B02
―
5902
―
6B03
―
5A02
―
6B04
―
5B02
―
6B0A
―
5C02
―
6C01
―
6001
The front cover sensor detected that
the front cover was open.
6C02
―
6002
―
6C03
―
6003
―
6C04
―
6004
The eject sensor detected that the
fuser cover was open.
6D00
―
6007
―
6E00
―
6101
The new toner sensor detected that
the toner cartridge was not set.
6F00 Detected irregular power supply for
less than 100 times.
6102
―
7000
The eject sensor does not detect
paper pass after the registration rear
sensor detected the paper pass.
6103
―
7001
―
6104
―
7002
―