2-69
Confidential
Completely blank
Image distortion
<User Check>
- Clean the corona wire of the drum unit.
- Replace the drum unit with a new one.
- Replace the toner cartridge with a new one.
- Install the latest firmware.
Step
Cause
Remedy
1
Dirt on the electrodes of the drum
unit and those of the machine
Clean the electrodes of the drum unit and
those of the machine. (Refer to
and
2
Dirt on the electrodes of the toner
cartridge and those of the machine
Clean the electrodes of the toner cartridge
and those of the machine. (Refer to
and
3
Connection failure of the laser unit
flat cable
Reconnect the laser unit flat cable.
4
Laser unit attachment failure
Reattach the laser unit.
5
Laser unit flat cable failure
Replace the laser unit flat cable.
6
Dirt on the electrodes of the high-
voltage power supply PCB
Clean the electrodes of the machine.
(Refer to
7
Laser unit failure
Replace the laser unit.
8
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Laser unit attachment failure
Reattach the laser unit.
2
Laser unit failure
Replace the laser unit.
3
Main PCB failure
Replace the main PCB ASSY.