BES-941BC • BES-1241BC
171
Chapter 10 Troubleshooting
Symptom
Measures
• Is thread tangled in the rotary hook?
Clean the rotary hook.
• Is the lower shaft with which the error occurs rotating?
If so, check to see if connection from the lower shaft sensor PCB to
the BC PCB is proper. Adjust the lower shaft sensor. Replace the
lower shaft sensor PCB with a new one.
• If the lower shaft with which the error occurs is not rotating, check to
see if connection from the lower shaft motor to the BC PCB is proper.
Replace the lower shaft module with a new one. Replace the BC PCB
with a new one.
The lower shaft motor zero point er-
ror occurs.
• Is the rotary hook rotated manually?
This is not a fault.
• Check to see if connection from the lower shaft sensor PCB to the BC
PCB is proper. Replace the lower shaft module with a new one.
The lower shaft motor standby posi-
tion error occurs.
• Check to see if the lower shaft fan is normally rotating. If the fan is at
standstill, check to see if connection from the lower shaft fan to the BC
PCB is proper. Replace the lower shaft fan with a new one.
• If all the lower shaft fans are at standstill, check fuse F4 on the power
supply PCB in the control box.
• Is the hole next to the bed with which the error frequently occurs clogged
with dust?
If so, clean it.
• Check to see if connection from the thermister of the lower shaft module
to the BC PCB is proper.
The lower shaft overheat error oc-
curs.
• Is thread tangled in the rotary hook?
Clean the rotary hook.
• Conduct BC sensor test of the test mode.
If there is any failure, replace the lower shaft module with a new
one.
• Conduct automatic out-of-step limit measurement of BC automatic test
in the test mode.
Replace the lower shaft module with a new one if there is any fault.
• Check to see if the lower shaft fan of the head with which the error
frequently occurs is correctly rotating.
If the fan is at standstill, check to see if connection from the lower
shaft fan to the BC PCB is proper. Replace the lower shaft fan with a
new one.
• If all the lower shaft fans are at standstill, check fuse F4 on the power
supply PCB in the control box.
• Is the hole next to the bed with which the error frequently occurs clogged
with dust?
If so, clean it.
Thread is frequently tangled in the
rotary hook.
Summary of Contents for BES-1241BC
Page 7: ...5 BES 941BC BES 1241BC 2 1 7 1 6 3 4 5 7 3 2 Belt cover Finger guard BES 941BC ...
Page 13: ...11 BES 941BC BES 1241BC Setting of thread breakage sensor page 94 Setting of Machine page 97 ...
Page 18: ...16 BES 941BC BES 1241BC ...
Page 19: ...Chapter 1 Preparation of Embroidery Machine ...
Page 50: ...Chapter 1 Preparation of Embroidery Machine BES 941BC BES 1241BC 48 ...
Page 60: ...BES 941BC BES 1241BC 58 Chapter 2 Embroidering Procedures ...
Page 125: ...Chapter 6 Operation of Machine ...
Page 136: ...Chapter 6 Operation of Machine BES 941BC BES 1241BC 134 ...
Page 137: ...Chapter 7 Maintenance ...
Page 148: ...Chapter 7 Maintenance BES 941BC BES 1241BC 146 ...
Page 149: ...Chapter 8 Standard Adjustment ...
Page 161: ...Chapter 9 List of Error Messages ...
Page 166: ...BES 941BC BES 1241BC 164 Chapter 9 List of Error Messages ...
Page 179: ...Connection and Installation of Optional Equipment ...