background image

 

FT1-SB System Manual 

MA370 Iss. 2 

 

 

 

 

 

 

 

  

 

17 

5  PRODUCT GUARANTEE 

 

Brooks guarantees the FT1-SB  control and indicating panel for a period of either fifteen (15) 

months from the date of purchase or twelve (12) months from the date of installation, whichever 

is the lesser. If a product has any defect due to faulty workmanship or material it will upon return 

to Brooks be repaired or replaced free of charge. 

 

If FT1-SB panel, any smoke/heat detectors or any other equipment supplied by Brooks should 

become defective within the guarantee period, it must be returned to Brooks, with proof of purchase, 

carefully packaged, with the problem clearly stated. Brooks shall at its discretion repair or replace 

the faulty unit. If returning the complete product all accessories and documentation MUST be 

returned. 

 

This guarantee only applies to normal conditions of use and service, and does not cover damage 

caused to the product or its components as a result of an accident, neglect, misuse, unauthorized 

dismantling, or contamination howsoever caused, incorrect installation, careless handling or where 

repairs have been made or attempted by others.  Onsite warranty repairs are not part of this 

guarantee.  This guarantee excludes incidental and consequential damage. This guarantee does 

not cover costs associated with the removal and/or installation of equipment 

 

No other guarantees written or verbal are authorised to be made on behalf of Brooks. All other 

conditions and warranties whether expressed or implied are, to the extent permitted by law, 

hereby excluded. 

 

As Brooks has no control over the system's design, installation to the relevant Australian Standard 

or maintenance, the company and its agents take no responsibility for any damage, financial loss 

or injury caused to any equipment, property or persons resulting from the use of the FT1-SB 

system    

 

Do not interfere with any components of FT1-SB system or attempt to tamper with it. This will 

invalidate the guarantee, but more importantly may expose the user to shock or fire hazards. This 

guarantee is in addition to your statutory rights as a consumer. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Firetracker FT1-SB

Page 1: ...SYSTEM MANUAL FT1 SB Single Zone FireAlarm System...

Page 2: ...Issue Date Description Written By Checked By Draft 0 2 9 2008 Original Document A Shenouda C Orr Issue 1 4 11 11 Update drawing in figure 7 A Shenouda A Shenouda Issue 2 18 11 19 Change Brooks address...

Page 3: ...OLS AND INDICATIONS 9 3 1 LED FLASH FUNCTIONS 9 3 2 BUZZER INDICATING PATTERN 9 3 3 CONTROL FUNCTIONS 10 3 4 CONTROL OUTPUTS 10 3 4 1 Non supervised outputs 10 3 4 2 Supervised Output 11 3 5 ZONE INPU...

Page 4: ...e Input Circuit 12 Figure 6 FT1 SB Block Wiring Diagram 13 Figure 7 Control Termination Module Power Supply mounting 14 Figure 8 FT1 SB Front Display typical mounting 14 TABLE LIST Table 1 FT1 SB Spec...

Page 5: ...ors and auxiliary outputs are available on the termination module The termination module is interfaced to the display module via RS232 Only 4 wires are required to connect the front display module to...

Page 6: ...tact 30V 0 5 Amp Disable Relay Output Changeover zone disable relay contact 30V 0 5 Amp Dimensions Display Module 96mm x 96mm x 72mm H W D Termination Module 90mm x 106mm x 58mm H W D Power Supply 90m...

Page 7: ...lity is segregated and includes a separate controls and LED indicators for each function i e alarm test fault test and disable isolate A Power ON and Common Fault indicators are provided to indicate t...

Page 8: ...odule The termination and control module to be mounted on a DIN rail at a convenient location within the switchboard cabinet The module as shown in Figure 2 above provides the termination point for al...

Page 9: ...ow Figure 3 Din rail Power supply Features Universal AC input Short circuit Overload Over voltage Protections Can be installed on a 35mm DIN rail LED indicator for power on No load power consumption C...

Page 10: ...nction Power On Steady On Power On Zone Alarm Flashing Steady on Alarm Test True Alarm Zone Fault Flashing Steady Fault Test Open or short circuit fault Zone Disable Steady Zone outputs disabled Commo...

Page 11: ...tected and verified before the alarm relays and buzzer become active Fault Test Fault LED flashes once every second Fault relay activate Perform zone fault test It takes approximately 3 seconds for th...

Page 12: ...terminals on the control termination module The EOL resistor type is 47K 1 2W or 1W 1 metal film 3 5 Zone Input The zone input specifications and compatible devices are listed in Table 5 and Table 6...

Page 13: ...296 Panasonic Conventional enclosed heat detector 80 degrees 6297 Panasonic Conventional enclosed heat detector 100 degrees 6298 Panasonic Conventional enclosed heat detector 120 degrees MRCSRR Menvie...

Page 14: ...5A 24VDC 24VDC 0 5Amp SUPERVISED CONTACTRATING 0 5A 24VDC CONTACTRATING 0 5A 24VDC CONTACTRATING 0 5A 24VDC CONTACTRATING 5A 24VDC 240VAC ALARM OUTPUTS FAULT OUTPUTS N Figure 6 FT1 SB Block Wiring Dia...

Page 15: ...FT1 SB System Manual MA370 Iss 2 14 Figure 7 Control Termination Module Power Supply mounting Rear Front Figure 8 FT1 SB Front Display typical mounting...

Page 16: ...er ON LED on the power supply module is illuminated 2 On the front Display check that only the green Power ON LED is illuminated all other LED indicators should be extinguished 3 Measure the DC voltag...

Page 17: ...ted zone open circuit and check the following Zone fault LED and common fault LED Illuminate steady Buzzer is pulsing once every 3 seconds Fault relay on the Control Termination Module is de energized...

Page 18: ...cident neglect misuse unauthorized dismantling or contamination howsoever caused incorrect installation careless handling or where repairs have been made or attempted by others Onsite warranty repairs...

Page 19: ...ent Abbotsford VIC 3067 Ph 03 9879 5294 SA P O Box 101 Woodville SA 5011 729A Port Road Woodville SA 5011 Ph 08 8347 0000 QLD P O Box 511 Archerfield QLD 4108 2 49 Boyland Ave Coopers Plains QLD 4108...