37
The lack of sealing of the connection may cause the malfunction of the equipment.
The internal diameter of the connection pipe should correspond to the external diameter of the chimney of the equipment. This service is
assured by the pipes complying with DIN DIN 1298.
4.2
COATING AND INSTALLATION OF THE INSERT
When the insert is installed in a facing or an old chimney it is essential the space among the top and the sides of the equipment and the
fireproof material of the hood (which block the base of the chimney) will be constantly ventilated. For this reason, it is necessary to keep an
fresh air entry on the bottom of the facing and an exit on the top (hot air exit) by the hood. The function will be improved due to there is a
natural convection circuit. Every one of these openings must be free and not blocked with a surface of 3 dm2 at least (for example, grille 30
x 10 cm.).
D38
CONDUCTO METALICO
MAXIMA INCLINACION 45º
ESPACIO ENTRE EN TUBO Y
EL CONDUCTO SELLADO
CAMARA DE DESCOMPRESION
REJILLA
REJILLA
AISLAMIENTO LANA DE ROCA
REJILLA SALIDA AIRE CONVECCION
PROTEGER LAS PARTES
INTERNAS DE LA MADERA
ESPACIO ENTRE EL REVESTIMENTO Y EL INSERT
AISLAMIENTO LANA DE ROCA
ENTRADA AIRE FRIO
ENTRADA AIRE FRIO
ENTRADA AIRE FRIO
AISLAMIENTO LANA DE ROCA
PARED
50 cm
Metallic channel
maximum inclination 45º
Decompression chamber
Space between the pipe and
the sealed channel
Grate
Grate
Exit grate of the convection air
Rock wool insulation
Rock wool insulation
Protect the inner
walls of the wook
Space between the cladding and the insert
Cold air entry
Cold air entry
Cold air entry
Rock wool insulation
Wall
5 mm
5 cm
4.3
CHIMNEY COWL
The chimney draft also depends on the chimney cowl.
The chimney cowl should assure the smoke discharge even during windy days, having into account that it must exceed the top of the roof
(
drawing D39
).
D42
(1) Industrial chimney of
prefabricated elements
that allow a good smoke
extraction.
(2) Traditional chimney. The
proper exit section must be,
at least, two times the interior
section of the chimney, the best
is 2.5 times
3) Chimney with interior cone
smoke deflector.
D41
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
INSERTS
EN
Summary of Contents for BRISTOL