26
Forced ventilation
Some inserts are provided with axial fans of 160 m3/h each one, adequate to improve the heat distribution by
the ventilation of the room or the room beside.
However, the models Panamá E and F include a tangential turbine of 680 m3/h, while the Volga and Londres
models can optionally have the tangential turbine of 680 m3/h. These are called Volga-T and Londres-T.
The operation of the turbine of the models Panamá, Volga-T and Londres-T is explained in section 2.1.
In models with fans, the start and the control
of the ventilation is made by the three-position
switch placed on the right bottom side(
see
drawing D17
).
These three-positions have the following
functions:
-
0 position: the fans are turned off when there is no combustion inside
the chamber due to the stove is provided with a thermostat that
controls the fan according to the temperature of the insert.
-
1 position: the fans run in a low speed.
-
2 position: the fans run in a high speed.
Connection
In the right side of the insert you will find the cable that connects to the
network. It is advisable to not cut it in the entire length because this section
is useful when changes in the electrical components are needed.
It is obligated the correct connection of the installation to earth connection.
The installation of the system might be done by skilled labour and qualified under the current rules.
WARNING!!
The insert must be always connected to electrical network in order to, in case of a high
temperature, fans could start and dissipate the heat to the room where it is installed
or to any other adjacent room. The insert must never be unplugged from the network
when it is burning. In this case, the warranty of the insert shall terminate.
The inserts are provided with connections for two ventilation additional outputs.
To install them, follow the next steps:
a.
Remove the close covers of the air outputs placed at the high of the sump.
b.
Set the connection collars on the hole or holes.
c.
Drill the wall or existent hood to pass and install the fireproof flexible tubes (diameter of 12 cm)
with their corresponding connection.
d.
Set the tubes with metallic clamps to the corresponding collars and grilles. Every tube must not
exceed 3.5 m. long and it must be insulated with insulated materials to avoid noises and loss of
heat.
e.
The grilles must be placed higher than 2 meters over the floor to avoid the heat air annoy the
people.
2.1
LONDRES-T VISIÓN, VOLGA-T AND PANAMÁ SERIES CENTRAL UNIT
OFF
L1
L2
L3
L4
L5
MAN
AUTO
PROP
MENU
P1
P2
P3
P4
FUSE
SONDA
LINEA VENT.
230 Vac 230 Vac
External aspect and electrical connections
PRODUCT COMPOSITION
-
Boxed temperature controller 3 module
-
Cover Plate, Inbox box
-
Temperature Probe, Accessories, Instructions
D17
R 820 ohm
50 W
220 V
L
N
FANS
THERMOSTAT
CONNECTION TO
GROUND
INSTALLATION SUPPORT
COMMUTADOR 2
POSITIONS
CHASSIS OF THE
CONNECTION
TO GROUND
D18
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
INSERTS
EN
Summary of Contents for BRISTOL
Page 103: ...102 ...