15
7.4
Set charging dimmer on / off (dim)
The dim function can be switched on or off (on/--) by briefly pressing the "up/down" key
(10) of channel 1 (on / --). If the dim function is switched on, the modelling light will dim
(at mains/AC-lines, operation) respectively extinguish (at battery operation) when
charging takes place. This feature can be used as a visual flash monitor and to reduce
the current load on weak mains (AC-lines). To avoid overloading the mains supply, the
"dim" function remains permanently on during fast charge (see chapter 7.4) and can not
be deactivated. This also applies to operation with the Power Dock (battery operation).
7.5
Sequences (seq) (serial flashes)
This function permits to set a defined number of flash discharges from 1 to 50. By
briefly pressing the flash energy control "up/down" key (10) of channel 1, select the
desired number of flashes. With a long pressure on the flash energy control "up/down"
key (10), change the settings in intervals of ten.
Each release signal triggers the selected number of flashes. A running sequence can be
stopped by briefly pressing the "
aux
" (22) key or by switching the unit off and on again.
This function is deactivated, when the number of flashes are set to "0" or the power
pack is switched off.
7.6
Studio / unit address (unit)
The power pack Verso A is also available as an unit version with integrated RFS inter-
face (
R
adio
F
requency
S
ystem). The function "unit" (23) allows to assign to each RFS
unit an individual unit address and a studio workstation (remote control channel) .
Attention: At present the power packs Verso RFS can not be activated individually in a
studio. The update of the "bron studio" software is in preparation.
Assignment of unit address:
Select the LED "unit" with the "
aux
" key (22). On the LCD display of channel 2 (9) the
letter "U" appears. On the LCD display of channel 1 (8) the set unit address appears. By
briefly pressing the flash energy control keys "up/down" (10) of channel 1 the desired
power pack address can be assigned. With a long pressure on the flash energy control
keys "up/down" the setting changes in intervals of ten. It is possible to assign per studio
workstation up to 20 different unit addresses ("01" to "20"). For the correct functioning of
the remote control via radio, each unit must be assigned with its own unit address.
Assignment of studio workstation:
When re-pressing the "
aux
" key the letters "CH" will appear on the LCD display of
channel 2 (9). On the LCD display of channel 1 (8) the set studio number will appear. By
briefly pressing the flash energy control keys "up/down" (10) of channel 1 the desired
studio number can be assigned. With a long pressure on the flash energy control keys
"up/down" the setting changes in intervals of ten. It is possible to assign up to 10
workstations ("01 to 10"). All units, which are to be triggered using the same camera,
must have the same studio number.
Summary of Contents for Verso A2 plus
Page 5: ...5 also valid for Verso A4 ...