16
8. Basic settings ex works
The basic settings ex works can be viewed and in some instances changed with the
following procedure:
When the unit is switched on press the keys "
mod
" (14) and "
aux
" (22) at the same
time for approx. 5 sec. (the blinking of the LED array "prop" / "fast" / "buz" / "dim" / "seq"
/ "unit" shows the programming mode).
On the LCD display of channel 2 (9) the selected function number will appear, and on
the LCD display of channel 1 (8) the actual value respectively the actual setting within
the selected function number is shown. Both values can be altered by using the flash
energy control keys "up/down" (10/11). With a long pressure on the flash energy control
keys "up/down" the setting changes in intervals of ten.
Within the function numbers 1 to 5 and 11 the settings can be changed with the flash
energy control keys "up/down". The function numbers 0, 6, 9 and 10 can be shown in
different pairs of those multi-digit values.
Return to normal operation by pressing (1 sec) the "
aux
" key or by switching off and on
again the unit or automatically after a waiting time of 20 sec.
Function number Meaning and possible settings
0
Program index:
Standard display (
XX.
xx)
Program number:
By pressing flash energy control key
"down" (xx.
XX
)
The power pack is equipped with 3 microprocessors and a fourth
one in the Power Dock unit. By pressing the energy control key
"up" several times, the 4 program indices can be selected.
1
Definition function "ir/rf" (see chapter 5)
Setting ex works: LCD display shows the value "3"
= IR receiver and RFS interface (if available)
activated.
Display value "1" = only RFS interface activated.
Display value "2" = only IR receiver activated.
2
Definition of limitation of the on time of modelling light
Setting ex works: 3 min.
By pressing the flash energy control keys "up/down" set the time
duration between 1 min. and 20 min. (see chapter 13 for details
and exceptions).
3
Mains voltage modelling light with battery operation (see chapter
4.3)
The unit selects the mains voltage of the modelling light auto-
matically. The mains voltage can be selected manually if desired:
by pressing the flash energy regulation keys "up/down" set the
desired mains voltage.
Display value "11" = Mains voltage 110 V
Display value "22" = Mains voltage 220 V
Summary of Contents for Verso A2 plus