8
2. Loosen the two quick release fasteners on both sides of the Power Dock (32 / 36)
and remove the cover (29).
3. Unplug the mains cable from the power pack.
4. The connection socket (31) for the contact plug and the three holes for the centring
pins (35) of the Power Dock are located on the bottom of the power pack Verso A.
Make sure that the contact plug of the Power Dock is clean, to guarantee a faultless
contact.
5. Place the bottom of the power pack Verso A on top of the upper side of the Power
Dock. The connection sockets of the mains cable must be located on the same side
of the power pack and Power Dock (27/34).Then connect the power pack Verso A to
the Power Dock. The connection socket for the mains supply (27) is thereby closed
by a sliding lock. Then hook in the quick release fasteners (32 / 36) of the Power
Dock to the corresponding holders of the power pack (28) pressing them gently to
close.
6. Switch on power pack using the mains switch (1).
2.2.2
Start up
Use the mains (AC-line) switch (1) to power-up unit. The LCD displays for the flash
energy (8 / 9) show the activated channels as well as their set values. Due to the
automatic lamp unit detection of the power pack the corresponding channel is automati-
cally activated as soon as one of the three outlets (5 / 6) is occupied. Additionally the
green control lamp of the visual ready display lights up (15).
Verso A is equipped with an acoustic warning system in respect of the charge state of
the battery. If the remaining battery energy has reached 50 %, it will be indicated by an
audible warning signal (7) and the flashing of the display. On reaching the energy level
of 10 % a new audible warning signal is emitted and the battery warning signal display
starts to flash permanently. If the battery is empty, the Verso A sends a warning signal
and after 5 sec. both the power pack and the Power Dock are switched off. The battery
package of the Power Dock must be recharged.
2.2.3
Automatic switch-off of the power pack
To protect the battery, the power pack is provided with the option "automatic switch-off".
If desired, the waiting time can be set between 10 min. and 99 min. When reached, the
power pack switches off automatically (see chapter 8). Independent from this setting,
the power pack switches to economy mode 1 min. after the last operation, which is
visible from the slightly dimmed flashing display. Flash release is still possible on
economy mode.