Brodie AddPak Installation & Operation Manual Download Page 7

IOM AddPak R02

Page 7/24

3.1 - Limited Warranty Continued 

A decontamination statement, RMA, and Customer 
Problem Report must also accompany equipment 
returned. Product received in an unsuitable con-
dition will be returned at Buyer’s expense without 
being examined. 

Goods repaired, and parts replaced during the  
warranty period shall be in warranty for the         
remainder of the original warranty period or    
ninety (90) days, whichever is longer. 

This limited warranty is the only warranty made 
by Brodie and can be amended only in a writing 
signed by an authorized representative of Brodie. 

Except as otherwise expressly provided in the 
Agreement, there are no representations or war-
ranties of any kind, expressed or implied, as to 
merchantability, fi tness for a particular purpose, or 
any other matter with respect to any of the goods 
or services.  

It is understood that corrosion or erosion of ma-
terials is not covered by our guarantee unless the 
Buyer has notifi ed the Seller the product will be 
used in an environment conducive to corrosion 
and/or erosion and the product has been coated 
with Brodie’s recommended method of protection 
against corrosion / erosion.

3.2 - Limitation of Remedy and Liability

Brodie International, a Brodie Meter Co., LLC Com-
pany (“Brodie”) shall not be liable for damages 
caused by delay in performance. 

The sole and exclusive remedy for breach of war-
ranty hereunder shall be limited to repair, correc-
tion, replacement or refund of purchase price un-
der the limited warranty clause in Section 1 herein. 

In no event, regardless of the form of the claim or 
cause of action (whether based in contract, in-
fringement, negligence, strict liability, other tort or 
otherwise), shall “Brodie’s” liability to buyer and/or 
its customers exceed the price to buyer of the spe-
cifi c goods manufactured or services provided by 
Brodie giving rise to the claim or cause of action.

Buyer agrees that in no event shall Brodie’s liabili-
ty to buyer and/or its customers extend to include 
incidental, consequential or punitive damages. 

The term “consequential damages” shall include, 
but not be limited to, loss of anticipated profi ts, 
loss of use, loss of revenue and cost of capital.

Brodie International
P.O. Box 450 (30459-0450)
19267 Highway 301 North
Statesboro, GA 30461, USA

www.brodieintl.com
Phone: +1 (912) 489-0200

Summary of Contents for AddPak

Page 1: ...IOM AddPak R02 Page 1 24 Brodie AddPak Additive Injection Block Installation Operation Manual...

Page 2: ...Receipt of Shipment 10 5 Return of Equipment 10 6 Storage 11 7 Standard Features 12 8 Functional Operation 14 9 Mounting 14 10 Specifications 15 11 Solenoid Input 17 12 Sensor Output 17 13 Wiring 18...

Page 3: ...trademarks of these companies The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed...

Page 4: ...iate instruction manual and per applicable local and national codes Connect all products to the proper electrical and pressure sources To ensure proper performance use qualified personnel to install o...

Page 5: ...responsibility to ensure that piping and other attachments connected to the Brodie instrument do not place adverse stresses upon it the design of the instrument has not been assessed for the effects o...

Page 6: ...nsuitable power sources unsuitable environmen tal conditions accident misuse improper instal lation modification repair storage or handling or any other cause not the fault of Brodie are not covered b...

Page 7: ...nd the product has been coated with Brodie s recommended method of protection against corrosion erosion 3 2 Limitation of Remedy and Liability Brodie International a Brodie Meter Co LLC Com pany Brodi...

Page 8: ...d to the factory A Decontamination Statement is included in the back of this manual If the equipment is removed from service it must be thoroughly drained and neutralized before it is packed for shipm...

Page 9: ...that the instrument be placed in an environmental ly controlled warehouse If this is not possible the instrument should be stored in a waterproof lined wooden box Desiccant packs should be taped to th...

Page 10: ...ar stock which minimizes external leak points The injector also incorporates an inlet machined basket strainer and an outlet check valve Installation The Injector s slim footprint allows for easy inst...

Page 11: ...y 0 25 Oval Gear Meter K Factor 5400 PPG Process Connections 3 8 FNPT Max Viscosity 300 Centistokes Max Working Pressure 400 PSI Electrical ASCO Explosion Proof Solenoid 120VAC 60HZ Standard Other Vol...

Page 12: ...ntroller as referenced above will send an AC voltage to the solenoid This will energize the coil and allow flow through the block As flow passes thru the block the oval meter will send pulses proporti...

Page 13: ...on Viton Chemraz Max Working Pressure 400PSI Environmental Ambient Operating Range 40 to 140 F Sensor Electrical Sensor Power 5vdc to 27vdc 20mA max imun Open Collector Output 5vdc to 27 vdc 100 mA ma...

Page 14: ...sor AB1010 1 11 Mounting Plate Sensor AB1011 1 12 Screws Socket Head Cap 10 32 x 3 8 Long 316 SS 151098 419 6 13 Sensor AB1012 1 14 Screws Socket Head Cap 6 32 x 7 16 151086 4 15 Quick Connect Stem Pr...

Page 15: ...aled on the face of the gear As flow passes through the block the oval gears rotate in direct pro portion to the volume and the sensor changes state as each magnet passes the sensor When the gear and...

Page 16: ...t sensor Isolate the shield at Meter Sensor and tape off Meter Sensor Pulse Signal Output The AddPak Injection Block meter sensor output is an un sourced open collector transistor output The white sen...

Page 17: ...itive pump to the AddPak must be sized to ensure adequate flow to meet the demand for injection Remember to consider how many injectors will be operating and the total flow required to meet that deman...

Page 18: ...Page 18 24 IOM AddPak R01 15 1 AddPak Unit Assembly...

Page 19: ...25 3 11 94 1 3 97 9 98 7 5 39 43 43 39 1 8 8 3 349 94 8 4 3 47 8 148 94 3 3 9 47 47 3 9 43 47 5 7843 54 7 8 551 5 18 4 39 7 42243 7 10 9 3 8 3 1 35 9 85 25 1 9 4958 8 7 TMRX 349 8 9MJ UT JW XZUUQ UNHY...

Page 20: ...Page 20 24 IOM AddPak R01 15 4 AddPak Illustration...

Page 21: ...IOM AddPak R02 Page 21 24 Technical Configuration STRAINER NEEDLE VALVE INJECTOR BLOCK CHECK VALVE NEEDLE VALVE QUICK DISCONNECT PULSE SENSOR SOLENOID OUTLET 3 8 NPT INLET 3 8 NPT...

Page 22: ...Health and Safety Hazards Precautions First Aid I hereby certify the equipment being returned has been cleaned and decontaminated in accordance with good industrial practices and in compliance with OS...

Page 23: ..._______________________ Additional Comments _______________________________ ___________________________________________________ Report Prepared by _________________________________ Phone _____________...

Page 24: ...Brodie International P O Box 450 30459 0450 19267 Highway 301 North Statesboro GA 30461 USA sales brodieintl com 1 912 489 0200 1 912 489 0294 Email Phone Fax...

Reviews: