3 Warranty Claim Procedures

3.1 - Limited Warranty

Subject to the limitations contained in Section 2 
herein and except as otherwise expressly provided 
herein, Brodie Meter Co., LLC (“Brodie”) warrants 
the Goods-manufactured by Brodie will be free 
from defects in materials or workmanship under 
normal use and care until the expiration of the 
applicable warranty period.  

Goods are warranted for twelve (12) months from 
the date of installation and 18 months from date 
of shipment, whichever occurs fi rst.  Consumables 
and Services are warranted for a period of 90 days 
from the date of shipment or completion of the 
Services.  

Products purchased by Brodie from a third party 
for resale to Buyer (“Resale Products”) shall carry 
only the warranty extended by the original manu-
facturer.  

Buyer agrees that Brodie has no liability for Resale 
Products beyond making a reasonable commercial 
effort to arrange for procurement and shipping of 
the Resale Products. 

If Buyer discovers any warranty defects and noti-
fi es Brodie thereof in writing during the applicable 
warranty period, Brodie shall, at its option, repair 
or replace, that portion of the Goods found by Bro-
die to be defective or refund the purchase price of 
the defective portion of the Goods/Services. 

All replacements or repairs necessitated by in-
adequate maintenance, normal wear and usage, 
unsuitable power sources, unsuitable environmen-
tal conditions, accident, misuse, improper instal-
lation, modifi cation, repair, storage or handling, 
or any other cause not the fault of Brodie, are not 
covered by this limited warranty, and shall be at 
Buyer’s expense.

 
Brodie shall not be obligated to pay any costs or 
charges incurred by Buyer or any other party ex-
cept as may be agreed upon in writing in advance 
by an authorized Brodie representative. 

All costs of dismantling, reinstallation and freight 
and the time and expenses of Brodie’s personnel 
for site travel and diagnosis under this warranty 
clause shall be borne by Buyer unless accepted in 
writing by Brodie. 

Brodie is not responsible for damages that in-
cur during shipment to Buyer for shipments that 
are F.O.B. Brodie Factory, FCA Brodie Factory, or 
EXWORKS Brodie Factory. Shipping charges for 
goods returned to Brodie under warranty will be at 
Buyer’s expense. 

Products found not to be warranted can be re-
paired and returned at Buyer’s expense and return 
charges born by Brodie will be added to the cost of 
repair or returned to Buyer “as received” at Buy-
er’s expense. Insurance for returned products will 
be at Buyer’s expense. 

For all returned products please package to pre-
vent damage, or future damage during shipment.

Make sure the products are cleaned, free from 
grease oil, chemicals and other materials that may 
hamper defect detection and impede repair. 

All returned items must be accompanied with a 
MSDS for the products that have been in contact 
with the equipment, including cleaning agents. 

Summary of Contents for AddPak

Page 1: ...IOM AddPak R02 Page 1 24 Brodie AddPak Additive Injection Block Installation Operation Manual...

Page 2: ...Receipt of Shipment 10 5 Return of Equipment 10 6 Storage 11 7 Standard Features 12 8 Functional Operation 14 9 Mounting 14 10 Specifications 15 11 Solenoid Input 17 12 Sensor Output 17 13 Wiring 18...

Page 3: ...trademarks of these companies The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed...

Page 4: ...iate instruction manual and per applicable local and national codes Connect all products to the proper electrical and pressure sources To ensure proper performance use qualified personnel to install o...

Page 5: ...responsibility to ensure that piping and other attachments connected to the Brodie instrument do not place adverse stresses upon it the design of the instrument has not been assessed for the effects o...

Page 6: ...nsuitable power sources unsuitable environmen tal conditions accident misuse improper instal lation modification repair storage or handling or any other cause not the fault of Brodie are not covered b...

Page 7: ...nd the product has been coated with Brodie s recommended method of protection against corrosion erosion 3 2 Limitation of Remedy and Liability Brodie International a Brodie Meter Co LLC Com pany Brodi...

Page 8: ...d to the factory A Decontamination Statement is included in the back of this manual If the equipment is removed from service it must be thoroughly drained and neutralized before it is packed for shipm...

Page 9: ...that the instrument be placed in an environmental ly controlled warehouse If this is not possible the instrument should be stored in a waterproof lined wooden box Desiccant packs should be taped to th...

Page 10: ...ar stock which minimizes external leak points The injector also incorporates an inlet machined basket strainer and an outlet check valve Installation The Injector s slim footprint allows for easy inst...

Page 11: ...y 0 25 Oval Gear Meter K Factor 5400 PPG Process Connections 3 8 FNPT Max Viscosity 300 Centistokes Max Working Pressure 400 PSI Electrical ASCO Explosion Proof Solenoid 120VAC 60HZ Standard Other Vol...

Page 12: ...ntroller as referenced above will send an AC voltage to the solenoid This will energize the coil and allow flow through the block As flow passes thru the block the oval meter will send pulses proporti...

Page 13: ...on Viton Chemraz Max Working Pressure 400PSI Environmental Ambient Operating Range 40 to 140 F Sensor Electrical Sensor Power 5vdc to 27vdc 20mA max imun Open Collector Output 5vdc to 27 vdc 100 mA ma...

Page 14: ...sor AB1010 1 11 Mounting Plate Sensor AB1011 1 12 Screws Socket Head Cap 10 32 x 3 8 Long 316 SS 151098 419 6 13 Sensor AB1012 1 14 Screws Socket Head Cap 6 32 x 7 16 151086 4 15 Quick Connect Stem Pr...

Page 15: ...aled on the face of the gear As flow passes through the block the oval gears rotate in direct pro portion to the volume and the sensor changes state as each magnet passes the sensor When the gear and...

Page 16: ...t sensor Isolate the shield at Meter Sensor and tape off Meter Sensor Pulse Signal Output The AddPak Injection Block meter sensor output is an un sourced open collector transistor output The white sen...

Page 17: ...itive pump to the AddPak must be sized to ensure adequate flow to meet the demand for injection Remember to consider how many injectors will be operating and the total flow required to meet that deman...

Page 18: ...Page 18 24 IOM AddPak R01 15 1 AddPak Unit Assembly...

Page 19: ...25 3 11 94 1 3 97 9 98 7 5 39 43 43 39 1 8 8 3 349 94 8 4 3 47 8 148 94 3 3 9 47 47 3 9 43 47 5 7843 54 7 8 551 5 18 4 39 7 42243 7 10 9 3 8 3 1 35 9 85 25 1 9 4958 8 7 TMRX 349 8 9MJ UT JW XZUUQ UNHY...

Page 20: ...Page 20 24 IOM AddPak R01 15 4 AddPak Illustration...

Page 21: ...IOM AddPak R02 Page 21 24 Technical Configuration STRAINER NEEDLE VALVE INJECTOR BLOCK CHECK VALVE NEEDLE VALVE QUICK DISCONNECT PULSE SENSOR SOLENOID OUTLET 3 8 NPT INLET 3 8 NPT...

Page 22: ...Health and Safety Hazards Precautions First Aid I hereby certify the equipment being returned has been cleaned and decontaminated in accordance with good industrial practices and in compliance with OS...

Page 23: ..._______________________ Additional Comments _______________________________ ___________________________________________________ Report Prepared by _________________________________ Phone _____________...

Page 24: ...Brodie International P O Box 450 30459 0450 19267 Highway 301 North Statesboro GA 30461 USA sales brodieintl com 1 912 489 0200 1 912 489 0294 Email Phone Fax...

Reviews: