198
Brocade MLXe Series Hardware Installation Guide
53-1003030-01
Replacing a power supply
6
21) 0 0 0 0
22) 0 0 0 0
23) 0 0 0 0
24) 0 0 0 0
25) 0 0 0 0
26) 0 0 0 0
27) 0 0 0 0
28) 0 0 0 0
29) 0 0 0 0
30) 0 0 0 0
31) 0 0 0 0
32) 0 0 0 0
Monitoring Threshold: 32 flaps/hour
In the example above, the configured power supply monitoring threshold is 32 cycles per hour.
You can also use the show running-config command to display the power supply monitoring
threshold configuration, as displayed in the following example.
Brocade#show running-config
Current configuration:
!
ver V5.4.0T163
module 1 br-mlx-2-port-100g-x
module 3 ni-mlx-48-port-1g-mrj21
!
!
!
no logging enable ntp
logging console
telnet login-retries 5
telnet server
power-supply monitoring threshold 32
username script password 8 $1$hR/..5B1$adiszoS76gLD9zIyFF1ER1
In the example above, the configured power supply monitoring threshold is 32 cycles per hour.
Use the following command to show the uptime of modules:
Brocade#show version | include time
Active Management uptime is 9 minutes 30 seconds
Standby Management uptime is 8 minutes 45 seconds
LP Slot 3 uptime is 8 minutes 48 seconds
LP Slot 4 uptime is 8 minutes 48 seconds
LP Slot 5 uptime is 8 minutes 50 seconds
LP Slot 6 uptime is 8 minutes 50 seconds
LP Slot 8 uptime is 8 minutes 48 seconds
Brocade#
Brocade# show version | include xmr
Compiled on Jul 9 2012 at 09:52:52 labeled as xmr05400b396
Compiled on Jul 9 2012 at 09:52:52 labeled as xmr05400b396
Brocade#