12–2
SOLID STATE CONTROLLER TIPS
GAS TIPS
COMPLAINT
CAUSE
REMEDY
Display reads FAIL
1.
There is a controller failure.
1.
Turn cook/filter switch OFF.
Contact service person.
Display reads HI
1.
Oil temperature too high.
1.
Turn cook/filter switch OFF.
Contact service person.
Display reads PROB
1.
There is a temperature sen-
sor probe failure.
1.
Turn cook/filter switch OFF.
Contact service person.
Display reads CHEC
1.
Gas valve not ON (2400GH)
2.
Pilot light will not light
(2400GH)
3.
Open or faulty wall fuse
4.
Oil temperature not rising
properly
1.
Turn ON.
2.
Turn ON manual gas shut off
valve.
3.
Check wall fuse or circuit
breaker.
4.
Turn cook/filter switch OFF.
Contact service person.
COMPLAINT
CAUSE
REMEDY
Pilot burner will not
ignite
1.
Gas valve OFF
2.
Air in pilot gas line
3.
Gas shut-off valve OFF
4.
Incoming gas pressure too
high
1.
Slide switch to ON.
2.
See “2400GH LIGHTING
INSTRUCTIONS” on page 5-
3.
3.
Turn ON.
4.
Install regulator to control
gas pressure.
Main burner will not
ignite
1.
Pilot burner not lit
2.
Gas control OFF
3.
Controller in program mode
4.
Cook/filter switch OFF
5.
Hi-limit tripped
1.
See “2400GH LIGHTING
INSTRUCTIONS” on page 5-
3.
2.
Turn ON.
3.
Exit program mode.
4.
Turn to COOK.
5.
Turn cook/filter switch OFF.
Contact service person.
broaster.com Manual #16285 8/05 Rev: 2/14
Summary of Contents for 2400XP
Page 2: ......
Page 4: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 20: ......
Page 24: ......
Page 28: ......
Page 32: ......
Page 38: ......
Page 40: ......
Page 42: ......
Page 50: ......
Page 51: ......
Page 52: ...The Broaster Company 2855 Cranston Road Beloit WI 53511 3991 608 365 0193 broaster com ...