BroadAccess CAG40D-MIN Installation Guide
P/N 760-000718 Rev A
March 2006
Page 13
Table 5.
Dipswitch Settings Used to Set System Number in Multiple CU
Systems
Dipswitch
System Number
9
10
1 Right Right
2 Left Right
3 Right Left
4 Left Left
3.2.4. CU Group Number
The CU Group Number, set through Dipswitches 16 and 17 on the CAG40D-MIN
backplane, is used for BroadAccess systems in which the CU is connected to the
local exchange through 2W connections in Automatic Connection Mode (if using
V5.x to connect the CU to the local exchange, use the management software
provided with your system to perform line provisioning accordingly).
Note:
The CU Group Number is not applicable for Manual Connection
Mode.
Table 6 details the dipswitch settings for each of the possible CU Group Number
options.
Table 6.
CU Group Number Dipswitch Settings (16-17) on CAG40D-MIN
Backplane
CU Cage No.
Dipswitch #2.
CU Group No.
DipSwitch 16
CU Group No.
DipSwitch 17
CU Slot No.
CU Subscriber
No.
1 (right)
Right
Right
1-4
1-64
1 (right)
Left
Right
5-8
65-128
1 (right)
Right
Left
9-12
129-192
1 (right)
Left
Left
13-15
193-240
2 (left)
Right
Right
1-4
241-304
2 (left)
Left
Right
5-8
305-268
2 (left)
Right
Left
9-12
369-432
2 (left)
Left
Left
13-15
433-480