23
Table 8: Master Controller Parameters Cont’d
Parameter ID
Number and
Value
(default)
Installer Parameter Description
Installer Parameter
Value Settings
Please
record
the values you
have set
n01 ID23:0
Heating Zone C - Unit
Heater ID No.
n01 ID24:3
Heating Zone C - Relay
Relay No. 1 to 4
n01 ID25:1
Heating Zone C - Temperature Sensing ID No.
Sensor No. 1 to 4
n01 ID26:0
Heating Zone D - Unit
Heater ID No.
n01 ID27:4
Heating Zone D - Relay
Relay No. 1 to 4
n01 ID28:1
Heating Zone D - Temperature Sensing ID No.
Sensor No. 1 to 4
n01 ID43:0
Heating - OFF Cycle Circulation Fan Operation
0 = OFF; 1 = ON
n01 ID73:1
Equipment Service Notification Message
0 = OFF; 1 = AUST; 2 = NZ
n01 ID92:0
Multi Set Point Control - Enable
0 = OFF; 1 = ON
n01 ID93:1
Refrig - Cooling Zone to Force Open
0 = None; 1=A; 2=B; 3=C; 4=D
n01 ID105:0
Heating - Enable Fan Scaling
0 = OFF; 1 = ON
n01 ID106:1
Heating - Common Zone Fan Speed
Range = 1 to 16
n01 ID107:1
Heating - Zone A Fan Speed
Range = 1 to 16
n01 ID108:1
Heating - Zone B Fan Speed
Range = 1 to 16
n01 ID109:1
Heating - Zone C Fan Speed
Range = 1 to 16
n01 ID110:1
Heating - Zone D Fan Speed
Range = 1 to 16
n01 ID111:0
Refrig - Enable Fan Scaling
0 = OFF; 1 = ON
n01 ID112:1
Refrig - Common Zone Fan Speed
Range = 1 to 16
n01 ID113:1
Refrig - Zone A Fan Speed
Range = 1 to 16
n01 ID114:1
Refrig - Zone B Fan Speed
Range = 1 to 16
n01 ID115:1
Refrig - Zone C Fan Speed
Range = 1 to 16
n01 ID116:1
Refrig - Zone D Fan Speed
Range = 1 to 16
Summary of Contents for ZonePlus B061006