3. Ductwork & Fittings
Size ductwork and fittings in accordance with good industry
practice; e.g. Australian Standard HB276 which prescribes
ductwork and diffusion equipment selection parameters. Do
not undersize ductwork and fittings. Ensure recommended
system minimum airflow requirements are met for both heating
and cooling modes.
4.0 GENERAL INSTALLATION
CONSIDERATIONS
•
The system design requirements would have been determined in
consultation with the home owner to correctly specify the
configuration and capabilities of the ZonePlus comfort control system
•
Ensure all power to all equipment and controls are off prior to
connecting
•
Ensure that all electrical connections are tight and secure. Install in
accordance with these instructions and your local laws, regulations
and standards
•
Use only twin-core, ‘figure 8’ – 0.75mm² cable for 2-wire bus
communications with less than 100m in total length
•
Ensure that the 2-wire bus cable is routed in a protected and safe
manner, away from mains power cabling
•
For additional product information refer to the Brivis product’s specific
Installer Manual
Varying Brivis StarPro heaters have different on-board
capabilities. See Table 2 for details of zone combinations
and accessory requirements.
Table 2: System Configuration & Accessory Summary
Note:
Unless otherwise specified, all instructions regarding ‘cooling’
relate to Brivs ICE Refrigerated Add-On Systems.