12
6.1.1 Setting NT-1 Sensor Identification
When the system contains more than one NT-1 device the
sensor identification parameter setting for additional sensors
must be changed using the
Jumper
inside the NT-1.
JUMPER
For NT-1 sensors other than the NT-1 for Zone B, change the
default position of the Jumper pin from position
“I/E”
to
position:
“S3”
for Zone C
“S4”
for Zone D
Jumper pin positions
“S5”
to
“S9”
are reserved for future
development.
6.2 ZonePlus with Multiple NC-6 and NT-1
Sensors
Table 4:
4-Zone System Configuration with 2xNC-6 and 2x
NT-1 (example)
Zone ID
Sensor
Type
Sensor
ID
Factory
Setting
Sensor
ID
System
Setting
To modify
Sensor ID
System
Setting
Zone A
NC-6
“n01”
“n01”
n/a
Zone B
NT-1
“n02”
“n02”
n/a
Zone C
NC-6
“n01”
“n03”
Installer
Parameter
“ID00:3”
Zone D
NT-1
“n02”
“n04”
Jumper
“S4”
Always set and record all parameters in the Appendix.
Important Notes:
•
NT-1 Sensors should be wired, configured and fully
installed
•
Only the NC-6 Controller backing plates should be wired
and installed
Power up the system in the following sequence:
•
516 Network Module (if applicable)
•
N-PM1 Power Module (if applicable)
•
Heater
•
Cooling System (if applicable)
I/E
S2
S3
S4
S5
S6
S7
S8
S9
AMBIENT
Jumper Pin
I/E
S2
S3
S4
S5
S6
S7
S8
S9
AMBIENT
Diagram 7.
Note:
NT-1 Temperature Sensors contain a green LED in the
top left hand corner. Whenever the NT-1 is being access by
an NC-6, the LED flashes once every second.