12.0 Brivis Iceberg Wall Control
Programmable thermostat has its own 7 wired loom which is interconnected between the unit
and the controller. Ensure there is a good connection on the board and the back of the wall
control.
Operating your wall control
The Iceberg Programmable Wall Controller gives the choice of Automatic or Manual modes with
the option of a time ON or OFF delay.
Automatic Pre-Wet
When the cooler is turned on with the fan and the pump, in either Auto or Manual mode, the
cooler will start a Pre-Wet stage to ensure the pads are thoroughly wet before the fan starts.
This contributed to the effective operation and performance of the cooler. The Pre-Wet time will
vary depending on how long the cooler has been OFF, and whether it needs to fill the tank prior
to operation.
Operating Modes
The cooler has several operating modes which are as follows:
1.”AUTO COOL”
2. “MANUAL”
3.”FAN ONLY”
Push the
MODE
key to cycle through the coolers operating modes.
Note: The wall control will remember previously established setting in Auto and Manual
Modes
On & Off
Button
Mode
Button
Timer
Button
Increase
Button
Decrease
Button
On Off
Indicator
light
Viewing