285 Issue 1 - Service Manual - Iceberg
12
2290 Min
Platform &
Service
Clearance
1
7
5
0
M
in
750 Min
Safety Tray
5
5
0
6
0
0
M
in
6
0
0
M
in
600
Location holes (x6) in “Safety
Tray” top hat for “Evaporator
Safety
Tray
Cable tie to secure water
supply braided hose
5.3 Platform & Service Clearances – Without Module
5.4 Electrical Power Supply to the Cooler
The Cooler is pre-wired with a 3-pin plug and lead, and should be plugged into a standard 10
Amp - 240 Volt power socket located within the roof space, in close proximity to the Evaporator
Module. The power socket should be wired back to the meter box on a dedicated power circuit.
IMPORTANT:
Switch OFF the power and unplug the Cooler before touching any internal cooler
breaker wiring. If any internal electrical wiring is damaged, it must be replaced by the
manufacturer, its service agents or an electrically qualified technician, in order to avoid a hazard.
The electricity supply must be 240 Volt / 50 Hertz, and from an authorised power supplier.
Generators should never be used, as their output may be incompatible with or damage the
Cooler’s electronic control system.
Cable tie to Secure Water
supply braided hose