background image

Quality Refrigeration

UHT27

ULT27

UPT276 UPT488

UPT6012

UHT48

ULT48

UPT279 UPT4812

UPT6018

UHT60

ULT60

UPT4818

UPT6024

This Traulsen unit is built to our highest quality standards.  We build our refrigerators, freezers and heated
cabinets this way as a matter of pride.  This philosophy has made Traulsen the leader in commercial refrig-
eration since 1938.  We thank you for your choice and confidence in Traulsen equipment and we know you
will receive many years of utility from this equipment.

All Traulsen units are placed on a permanent record file with the service department.  In the event of any
future questions you may have, please refer to the model and serial number found on the name tag affixed
to the unit.  Should you need service, however, call us on our toll free number, 800-825-8220 between 7:30
am and 4:30 pm CST, Monday thru Friday.  It is our pleasure to help and assist you in every possible way.

Traulsen & Co., Inc.

OWNER’S MANUAL

Instructions for the installation, operation,

 and maintenance of all Compact Undercounter

and Prep Table Models:

INSTALLER

COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION

INITIAL START DATE:

SERIAL NO.

MODEL TYPE:

COMPANY/INDIVIDUAL NAME:

INSTALLER:

FORM NUMBER TR35746 REV. 5/03

      P/N 375-60179-00

Quality Refrigeration

Summary of Contents for ULT27

Page 1: ...anent record file with the service department In the event of any future questions you may have please refer to the model and serial number found on the name tag affixed to the unit Should you need service however call us on our toll free number 800 825 8220 between 7 30 am and 4 30 pm CST Monday thru Friday It is our pleasure to help and assist you in every possible way Traulsen Co Inc OWNER S MA...

Page 2: ...al System Care Page 7 e Cleaning The Interior Page 7 VI MISC OPERATIONS a Rehinging The Door Page 8 b Preparing For Extended Shut Down Page 8 c Adjusting The Door Page 8 d Door Gasket Replacement Page 8 VII OTHER a Service Information Page 9 b Spare Parts Page 9 c Warranty Registration Page 9 VIII TROUBLESHOOTING GUIDE Page 10 IX PARTS LIST Page 11 X WARRANTY INFORMATION Page 13 XI INDEX Page 14 I...

Page 3: ...d during or immediately after installa tion contact the respective carrier and file a freight claim Under no condition may a damaged unit be re turned to Traulsen Co without first obtaining writ ten permission return authorization III a LOCATION Select a proper location for your Traulsen unit away from extreme heat or cold Condenser performance is dependent on adequate ventilation for cooling purp...

Page 4: ...ves and shelf clips are shipped with the unit For each shelf insert four 4 shelf clips into the pilaster slots at the same height Fig 3 The shelf clips have a small projection on top which holds the shelf in position and prevents it from slipping forwards After installing shelf clips on pilasters place shelves on clips III e CORD PLUG All UHT ULT UPT models are supplied with a cord plug attached I...

Page 5: ...is manual Place bottom unit near final installed location leaving access to rear for further assembly 2 Place stacking base on top of bottom unit NOTE The front of the stacking base must be oriented towards the front 3 Assemble two 1 4 20 x 5 8 screws through front mounting flange of stacking base into the threaded holes in the front of the top edge of the bottom unit Assemble five 10 16 x 1 2 scr...

Page 6: ...upport Secure with 2 threaded pins and 2 bolts per flange see figure 9 wider units may be equipped with an additional third pin in the center 3 Assemble cutting board to cutting board support pins holding cutting board support fit through holes in cutting board when properly aligned see figure 9 4 To install cover flex cover so side pins fit in holes at lower front corners of shelf see figure 9 Co...

Page 7: ...d to set when the next defrost cycle will start To adjust the defrost time control use a coin on the outside slot in the rim of the timer and turn clockwise until the compressor turns off Continue turning coin clockwise until the III l INSTALLING THE STAINLESS STEEL TOP All 27 48 and 60 wide compact undercounter models can be supplied with an optional stainless steel top This must be installed on ...

Page 8: ...ded To access the condensate removal box remove the lower panel at the rear of the equipment cabinet Clean the condensate removal box by wiping it out with a clean damp cloth using care with the condensate loop inside Replace the lower rear panel Reconnect electrical power supply WARNING DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY PARTS OF THE UNIT IV c DEFROST CONTROL CONT D compressor...

Page 9: ...ooked behind the gasket retainer Proceeding from this point out to the corners continue pushing the door gasket straight into the gasket retainer proceed doing the same to each of the remaining edges until the gasket is completely installed 8 VI MISC OPERATIONS Fig 14 Top Hinge Assembly Fig 15 Bottom Hinge Assembly Door Brass Bushing Lower RH Upper LH Hinge Plate Lower LH Upper RH Hinge Plate Door...

Page 10: ...service department at Traulsen Co Inc 4401 Blue Mound Road Fort Worth TX 76106 800 825 8220 Traulsen Co Inc reserves the right to change speci fications or discontinue models without notice VII b SPARE PARTS Spare or replacement parts may be obtained through a parts supplier or one of our authorized service agents A complete list of authorized service agents accompanies this manual and is also pos...

Page 11: ...e door was kept open for a long period of time in both cases allow adequate time for the cabinet to recover its normal operating temperature c Thermostat setting too high readjust per instructions on page 6 d Check that condensing coil is clean 4 Food compartment is too cold a Perhaps a large quantity of very cold or frozen food has recently been added Allow adequate time for the cabinet to recove...

Page 12: ...dels Shelf Upper SER 60273 00 Additional or Replacement Upper Shelf For 48 Wide Models Shelf Lower SER 60274 00 Additional or Replacement Lower Shelf For 48 Wide Models Shelf Upper SER 60272 00 Additional or Replacement Upper Shelf For 60 Wide Models Shelf Lower SER 60271 00 Additional or Replacement Lower Shelf For 60 Wide Models Shelf Clip SER 60269 00 Additional or Replacement Shelf Clip For Al...

Page 13: ...THE EQUIPMENT OR ITS SALE OPERATION OR USE AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE OPERATION OR USE OTHER THAN AS STATED HEREIN INTERNATIONAL COMMERCIAL WARRANTY for Canadian warranties see domestic US warranty TRAULSEN CO INC warrants to the original purchaser the Refrigeration Equipment manu...

Page 14: ... 13 ...

Page 15: ...ator Coil 7 Extended Shutdown Preparing For 8 F G H Hinge 8 I J K L Legs 2 3 M N O P Pallet Wooden 2 Pans Plastic 7 Parts Department 8 Parts Spare 8 Pilaster Slots 3 Power Supply 4 Prep Top Assembly 5 R Rehinging The Door 8 Return Authorization 2 S Sealant Silicone 4 Serial Tag 1 Shelf Clips 3 Shelves 3 Stacking Kit Installing 4 Stainless Steel Top Installing 6 T Thermostat 7 U Utility Base 4 V W ...

Page 16: ...ax Mktg 817 624 4302 Visit our on line repair service directory at www traulsen com Traulsen Co Inc 4401 Blue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax Svce 817 740 6757 Website www traulsen com HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Quality Refrigeration ...

Reviews: